Return to search

Influência do número de implantes no comportamento biomecânico de overdentures mandibulares : análise fotoelástica / Number of implant influence on the biomechanical behavior of mandibular overdentures : photoelastic stress analysis

Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T08:10:23Z (GMT). No. of bitstreams: 1
Campana_JuliaTrevizam_M.pdf: 13654859 bytes, checksum: 968de9ae31cd28485a92b1f5b52edc6c (MD5)
Previous issue date: 2015 / Resumo: O objetivo neste estudo in vitro foi avaliar por meio da análise fotoelástica o comportamento das tensões induzidas em diferentes overdentures. Os grupos experimentais foram: I- overdenture retida por um implante colocado na linha média da mandíbula; II- overdenture retida por dois implantes distantes 20 mm entre si; III- overdenture retida por três implantes, com o central colocado na linha média da mandíbula e os restantes distantes 18 mm de cada lado; e IV- overdenture retida por quatro implantes distantes 12 mm entre si. Para o estudo foi confeccionada uma prótese overdenture mandibular para cada grupo experimental e uma prótese total superior convencional, possibilitando que a análise fotoelástica fosse conduzida com as próteses se relacionando em máxima intercuspidação habitual. Foram feitos carregamentos axiais de 10, 20 e 30 kgf em cada modelo fotoelástico mandibular. Também foi realizado carregamento na oclusal dos primeiros molares direito e esquerdo de cada modelo com mesma intensidade de carga, para simular o efeito da mastigação. Dois tipos de avaliação foram conduzidos: qualitativa, por meio da análise das imagens obtidas com fotografias do modelo em polariscópio, e quantitativa, com as imagens analisadas no programa FRINGES. A análise qualitativa mostrou que a distribuição das tensões no Grupo I foi diferente dos Grupos II, III e IV, com maior quantidade de franjas concentradas na região posterior da mandíbula. O grupo IV apresentou melhor distribuição de tensão quando comparado aos Grupos II e III. Na análise quantitativa, a overdenture retida por um implante (Grupo I) mostrou valores de tensão similares aos Grupos II, III e IV. Com base nesses resultados pode-se concluir que: em todas as overdentures a tensão se concentrou predominantemente ao redor dos implantes; o aumento do carregamento oclusal ou pontual promoveu aumento das tensões induzidas sobre os implantes; maior tensão foi induzida no lado da aplicação da carga pontual, principalmente, quando a overdenture era suportada por um implante, e a concentração da tensão em overdenture suportada por maior quantidade de implante mostrou distribuição mais homogenia das tensões induzidas / Abstract: The aim of this in vitro study was to evaluate through photoelastic analysis the behavior of the induced stress in different overdentures. The experimental groups were: I- overdenture retained by one implant placed in the midline of the mandible; II- overdenture retained by two implants 20 mm distant from each other; III- overdenture retained by three implants, with the center placed on the midline of the mandible and the other distant 18 mm on each side; and IV- overdenture retained by four implants 12 mm distant from each other. For the study was made a prosthetic mandibular overdenture for each experimental group and a conventional complete denture, allowing the photoelastic analysis was conducted with the dentures related in maximum intercuspation. Axial loads of 10, 20 and 30 kgf were made in each mandibular photoelastic model. It was also performed on the occlusal loading of the first left and right molars of each model with similar load intensity to simulate the effect of mastication. Two types of evaluation were conducted: qualitative, by analyzing the images from photographs obtained with polariscope, and quantitative, with the images analyzed by the FRINGES program. Qualitative analysis showed that the distribution of tensions in Group I was different from the Groups II, III and IV, showing a higher amount of concentrated fringes on the posterior region of the mandible. Group IV showed better stress distribution when compared to Groups II and III. In the quantitative analysis, the overdenture retained by implant (Group I) showed similar stress values for Groups II, III and IV. Based on these results, it can be concluded that in all overdentures the stresses focused predominantly around the implants; increased single and occlusal loading promoted an increase of induced stresses on the implants; higher stress was induced on the application side, especially when the overdenture was supported by one implant; and stress concentration in overdenture supported by a larger amount of implantation showed more homogeneous stress distribution / Mestrado / Protese Dental / Mestra em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288538
Date27 August 2018
CreatorsCampana, Júlia Trevizam, 1989-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Rafael Leonardo Xediek, 1974-, Mesquita, Marcelo Ferraz, Reis, José Maurício dos Santos Nunes
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format121 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0078 seconds