Return to search

Inter-stage and Performance Tests of a Two-stage High-pressure Turbine

The existing 3-stage research turbine at Turbomachinery Performance and Flow Research Laboratory (TPFL) facility, Texas A & M University (TAMU) was replaced with a newly designed and manufactured 2-stage turbine in accordance with the design requirements as per DooSan, DHI. This new design of turbine consisted of bowed stator and rotor blades to study the effect on reduction of secondary ow losses and thus improvement in turbine efficiency if any. The new design also incorporated labyrinth seals on both inner and outer shrouds. Extensive Inter-stage and Performance experiments were carried out on this new turbine. Inter-stage measurements were accomplished by traversing three 5-hole probes radially and circumferentially, using the existing probe traverse system in TPFL. Performance tests were conducted for varying pressure ratio, at fixed rotational speed and for varying rotational speed with fixed pressure ratio and the efficiency was plotted against u/c_0. Each condition was tested and measured two to three times to check for reproducibility of the data.

The results from inter-stage experiments show that the rotor row loss coefficient is about four times higher than the stator row loss coefficient. This high rotor loss coefficient reduces the total to static efficiency. From the performance tests, the maximum total-to-static efficiency observed was 85.2 percent located at around u/c_0 = 0.75. This relatively low efficiency is in consonance with the inter-stage results (high rotor loss coefficient).

Identiferoai:union.ndltd.org:tamu.edu/oai:repository.tamu.edu:1969.1/ETD-TAMU-2011-05-9090
Date2011 May 1900
CreatorsSharma, Kapil
ContributorsSchobeiri, M T.
Source SetsTexas A and M University
Languageen_US
Detected LanguageEnglish
Typethesis, text
Formatapplication/pdf

Page generated in 0.0024 seconds