In the present study, the influence of geometric scale, unit orientation (alternatively, flow direction), and the dimensionless Reynolds and Keulegan-Carpenter quantities on the hydrodynamic loading of Core-Loc armour units is explored through a series of physical modelling tests under unsteady and oscillatory flow conditions.