Return to search

Estudo de dois sistemas radiograficos digitais submetidos a diferentes condições de trabalho em relação ao ruido

Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T08:05:18Z (GMT). No. of bitstreams: 1
Paganini_GiselaAndre_D.pdf: 3622509 bytes, checksum: 0a3a66ef45c71d609b9b77961f928382 (MD5)
Previous issue date: 2001 / Resumo: O presente trabalho teve como objetivo avaliar o ruído de imagens digitais dos sistemas Digora e DenOptix em diferentes graus de luminosidade do ambiente onde os sensores eram manipulados para serem introduzidos no scanner e lugares onde os sensores foram posicionados em relação ao monitor com tempos de espera pré-fixados. Foi estudado também o tempo total de dessensibilização da placa de fósforo do sistema DenOptix, expondo-as a negatoscópios de diferentes intensidade de luz. A análise objetiva das imagens de phantoms foi realizada utilizando-se pacote computacional "LISIER". A análise dos resultados mostrou que o sistema Digora ofereceu melhor qualidade de imagem com menor quantidade de ruído em relação ao sistema DenOptix, não se alterando sob as diferentes condições de luminosidade do ambiente. Para o sistema DenOptix, quando a leitura foi realizada em ambiente com a luz acesa, ocorreu um aumento do ruído nas placas, não sendo porém, subjetivamente significante. Com relação ao posicionamento dos sensores, com o acréscimo do tempo houve um aumento na quantidade de ruído detectada na imagem e o ruído foi maior nos sensores posicionados lateralmente ao monitor. Pela análise subjetiva das imagens digitais, não foi possível perceber nenhuma influência da iluminação ou da radiação emitida pelo monitor. Em relação à dessensibilização da placa do sistema DenOptix, negatoscópio. Pode-se concluir que este fator está diretamente relacionado com a dose de radiação aplicada ao sensor de placa de fósforo e com a intensidade da luz do negatoscópio / Abstract: The aim of the present work was to evaluate the noise in the digital images of the systems Digora and DenOptix in different intensity light environment. It was toa studied the time total to erase the plate of system DenOptix. The objective analysis of the phantoms images was carried through by means a computacional programo The results had show that the Digora system had the best image quality with low noise without alteration in different condition of the environment DenOptix system, when the read was realized in environment with light on, it had a increase of the noise but without estatistic difference. With relation on the sensors position, with the increase of the time, increased the noise in the image in lateral position on the sensors wasgreater. Than in front of the monitor the subjective assessment do not show the influence of the environment light or the radiation of the computer. In related a erasing the plate of system DenOptix, it conc1uded that this factor is direct associated to the radiation dose and the intensity of light of the negatoscope / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289000
Date31 October 2001
CreatorsPaganini, Gisela Andre
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Haiter Neto, Francisco, 1964-, Castilho, Julio Cezar de Melo, Freitas, Claudio de, Almeida, Solange Maria de, Boscolo, Frab Norberto
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format122p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds