Return to search

Análise fotoelástica das tensões e resistência mecânica de infraestruturas de titânio sobre implantes após soldagem a Laser e TIG / Photoelastic analysis of stress and mechanical framework titanium implant after welding and TIG

Orientador: Mauro Antonio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:53:34Z (GMT). No. of bitstreams: 1
Silva_MairaDayseMoreiraSerrae_M.pdf: 4885020 bytes, checksum: 8933e2fbe0ea03e889685d1620189f34 (MD5)
Previous issue date: 2011 / Resumo: Para o sucesso da permanência dos implantes ¿in loco¿ e da reabilitação protética, destaca-se a biomecânica como um fator fundamental. Com o objetivo de obter estruturas metálicas com melhor assentamento e maior resistência mecânica este estudo avaliou, comparativamente, duas técnicas de soldagem a Laser Nd: YAG (neodínio iátrio alumínio garnet), (Desktop Laser ¿ Dentaurum JP Winkelstroter KG, Pforzhein, Alemanha) e Tungstênio Gás Inerte (TIG) (Solda Plasma Micropulsada Micromelt - EDG, São Carlos, SP, Brasil). Por meio de análise fotoelástica e ensaios de resistência à flexão, foi avaliada a distribuição das tensões geradas ao redor de implantes em próteses implantossuportadas, tipo ¿protocolo¿ inferior, bem como a resistência dos cantilevers. Foram confeccionadas 15 infraestruturas em titânio sobre uma matriz metálica, em forma de arco, contendo quatro análogos de implantes do tipo hexágono externo, de diâmetro regular (3,75 X 13mm). Os corpos-de-prova foram separados em três grupos: GI, ou grupo controle, formado por infraestruturas de titânio comercialmente puro (Ti cp) em monobloco; GII, infraestruturas soldadas a Laser e GIII, soldadas a TIG. Para análise das tensões foi confeccionado um modelo fotoelástico (Resina Flexível / Polipox® Indústria e Comércio Ltda), seguido do posicionamento das infraestruturas, e através de um polariscópio circular foram avaliados trinta e nove pontos ao redor dos implantes, após torque de 20Ncm nos parafusos e quantificado as franjas obtendo valores de tensão cisalhante a partir da ¿Lei Ótica das Tensões¿. Em seguida, foi realizado o ensaio mecânico de resistência à flexão em uma máquina de ensaios universais (Instron). Os dados obtidos foram submetidos à análise de variância (um e dois fatores), seguida do teste de Tukey para comparação entre as médias, com nível de significância p?0,05. Os resultados mostraram não haver diferença estatística entre os valores de tensão cisalhante (?) para as duas técnicas de soldagem, porém, as estruturas em monobloco apresentaram menores valores de tensão, com diferença estatística em relação à solda TIG. Quanto ao ensaio mecânico, resultados estatisticamente diferentes entre as técnicas foram obtidos, sendo o grupo I, o de maior resistência mecânica à flexão, seguido pela solda Laser e TIG. Baseados nos resultados obtidos, pode-se concluir que a técnica de fundição é que apresenta maior resistência mecânica à flexão. / Abstract: For the success of the permanence ¿in loco¿ implants and the rehabilitation, biomechanical is a very important factor. Aiming to obtain frameworks with better fit, this study compared one-piece casted frameworks to frameworks obtained by two different soldering techniques: Laser-welding Nd: YAG (neodínio iátrio alumínio garnet), (Desktop Laser - Dentaurum Winkelstroter KG, Pforzhein, Germany) and Tungsten Inert Gas (TIG - Plasma Micropulse Micromelt - EDG, Sao Carlos, SP, Brazil). Thru photoelastic analysis and flexural strength tests, the stress distribution around implants and the mechanical resistance of the frameworks were evaluated. Fifteen commercially pure titanium frameworks were obtained using a steel matrix, with four external-hexagon regular-diameter (3.75 x 13mm) implants (Branemark protocol). The frameworks were divided into three groups: GI, or control group - one-piece casted frameworks; GII - Laser welded frameworks; GIII ¿ TIG welded frameworks. For stress analysis a photoelastic model, reproducing the steel matrix was manufactured with photoelastic flexible resin (Polipox® Industry and Trade Ltd.). Each framework was screwed with 20Ncm torque to the photoelastic models? implants through a circular polariscope, the order of the isochromatic fringes at thirty nine predetermined points around the implants was obtained. Maximum sheer stress was determined for each point through the ¿stress optical law¿. Then, a mechanical testing of flexural strength was performed at the hanging arms? joints of each framework. The data were submitted to ANOVA (One-Way and Two-Way), followed by Tukey test (p ? 0.05). The results showed no statistical difference between shear stress values (?) between the welding techniques, but the casting technique showed lower stress values, with statistical difference compared to TIG welding. As for the mechanical test, statistically different results between the techniques were obtained, GI presented higher ductility, followed by laser welding and TIG. Based on these results, it was concluded that the conventional casting technique is more mechanically resistant than the welding techniques. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288287
Date17 August 2018
CreatorsSilva, Maíra Daysê Moreira Serra e
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Nóbilo, Mauro Antonio de Arruda, 1965-, Lira, Andrea Fabiana de, Consani, Rafael Leonardo Xediek
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format130 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds