Previous issue date: 2013-05-17 / The aim of this study was to evaluate the potential of near-infrared reflectance
spectroscopy (NIRS) as a rapid and non-destructive method to determine the soluble
solid content (SSC), pH and titratable acidity of intact plums. Samples of plum with a
total solids content ranging from 5.7 to 15%, pH from 2.72 to 3.84 and titratable acidity
from 0.88 a 3.6% were collected from supermarkets in Natal-Brazil, and NIR spectra
were acquired in the 714 2500 nm range. A comparison of several multivariate
calibration techniques with respect to several pre-processing data and variable selection
algorithms, such as interval Partial Least Squares (iPLS), genetic algorithm (GA),
successive projections algorithm (SPA) and ordered predictors selection (OPS), was
performed. Validation models for SSC, pH and titratable acidity had a coefficient of
correlation (R) of 0.95 0.90 and 0.80, as well as a root mean square error of prediction
(RMSEP) of 0.45?Brix, 0.07 and 0.40%, respectively. From these results, it can be
concluded that NIR spectroscopy can be used as a non-destructive alternative for
measuring the SSC, pH and titratable acidity in plums / O objetivo deste estudo foi avaliar a potencialidade da espectroscopia no
infravermelho pr?ximo (NIRS) como um m?todo r?pido e n?o destrutivo para
determina??o do teor de s?lidos sol?veis (TSS), pH e acidez titul?vel em ameixas
intactas. Amostras de ameixa com teor de s?lidos sol?veis variando de 5,7 a 15%, pH
de 2,72 a 3,84 e acidez de 0,88 a 3,6% foram adquiridas de supermercados em Natal -
Brasil, e foram coletados espectros NIR no intervalo de 714-2500 nm. Uma compara??o
de v?rias t?cnicas de calibra??o multivariada com rela??o ao pr?-processamento dos
dados e algoritmos de sele??o de vari?veis, tais como m?nimos quadrados parciais por
intervalos (iPLS), o algoritmo gen?tico (GA), algoritmo das proje??es sucessivas
(SPA), e sele??o de previsores ordenados (OPS) foi realizada. Modelos de valida??o
para o teor de s?lidos sol?veis, pH e acidez titul?vel tiveram um coeficiente de
correla??o (R) de 0,95 a 0,90 e 0,80, bem como um erro m?dio quadr?tico de previs?o
(RMSEP) de 0,45? Brix, 0,07 e 0,40%, respectivamente. A partir desses resultados,
pode concluir-se que a espectroscopia NIR pode ser utilizada como uma alternativa n?o
destrutiva para determina??o do teor de s?lidos sol?veis, pH e acidez em ameixas
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/17722 |
Date | 17 May 2013 |
Creators | Costa, Rosangela C?mara |
Contributors | CPF:03144855464, http://lattes.cnpq.br/6928918856031880, Mata, Ana L?cia de Medeiros Lula da, CPF:14086034468, http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787367Y9, Rocha, Werickson Fortunato de Carvalho, CPF:05394736693, http://lattes.cnpq.br/1030306192969513, Lima, K?ssio Michell Gomes de |
Publisher | Universidade Federal do Rio Grande do Norte, Programa de P?s-Gradua??o em Qu?mica, UFRN, BR, F?sico-Qu?mica; Qu?mica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0181 seconds