Submitted by FERNANDO PARRA DOS ANJOS LIMA null (engfernandoparra@gmail.com) on 2016-10-31T11:47:54Z
No. of bitstreams: 1
Fernando Parra A. Lima.pdf: 3667307 bytes, checksum: 0d206b9c09566cdb11de101b84976228 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-11-07T16:42:09Z (GMT) No. of bitstreams: 1
lima_fpa_dr_ilha.pdf: 3363973 bytes, checksum: d8849cdd159a11920c497d025a8ae16a (MD5) / Made available in DSpace on 2016-11-07T16:42:09Z (GMT). No. of bitstreams: 1
lima_fpa_dr_ilha.pdf: 3363973 bytes, checksum: d8849cdd159a11920c497d025a8ae16a (MD5)
Previous issue date: 2016-09-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta pesquisa é dedicada ao desenvolvimento de uma metodologia para a realização do diagnóstico de distúrbios de tensão de sistemas de distribuição de energia elétrica, baseada no uso de sistemas imunológicos artificiais (SIA). Trata-se da proposição de um novo paradigma no ambiente dos SIA que confere o aprendizado de modo contínuo (plasticidade). Esta concepção permite compor um sistema de diagnóstico apto a aprender continuamente, contemplando novos tipos de distúrbios advindos da constante evolução do setor elétrico, sem a necessidade de reiniciar o processo de aprendizado. Neste contexto, empregam-se dois algoritmos imunológicos artificiais, sendo o algoritmo de seleção negativa, responsável pelo processo de reconhecimento de padrões, e o algoritmo de seleção clonal responsável pelo processo de aprendizado. A principal aplicação deste novo método é auxiliar na operação do sistema durante distúrbios, bem como, supervisionar o sistema de proteção, e estar apto a acompanhar a evolução dos sistemas elétricos adquirindo conhecimento continuamente. Para avaliar a eficácia e o desempenho deste novo método foram realizadas simulações de distúrbios de tensão em sistemas de distribuições de energia elétrica com 5, 33, 84 e 134 barras, no software ATP/EMTP. Os resultados obtidos com esta abordagem mostram robustez e eficiência quando comparados à literatura. / This work develops a methodology to realize voltage disturbance diagnosis in electrical distribution systems, based on Artificial Immune Systems (AIS). It is a proposition of a new paradigm in AIS environment, which provides a continuous learning (plasticity). This conception allows composing a diagnosis system able to continuous learn, when new disturbances appear due to the constant evolution of the power systems, without needing to reinitialize the learning. This way, two artificial immune algorithms are used, such as the negative selection algorithm executing the pattern recognition process, and the clonal selection algorithm, executing the learning process. The main application of this new method is to aid the system operation during disturbances, as well as, supervise the system protection and be able to carry on the evolution of the electrical systems acquiring knowledge continuously. To evaluate the efficiency and the performance of this new method, voltage disturbance simulations were executed in electrical distributions systems with 5, 33, 84 and 134-bus in ATP/EMTP software. Results show robustness and efficiency when compared with those in the literature.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/144531 |
Date | 01 September 2016 |
Creators | Lima, Fernando Parra dos Anjos [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Minussi, Carlos Roberto [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | 600 |
Page generated in 0.1314 seconds