Return to search

DEVELOPMENT OF 15 PSI SAFE HAVEN POLYCARBONATE WALLS FOR USE IN UNDERGROUND COAL MINES

Following three major mining accidents in 2006, the MINER Act of 2006 was enacted by MSHA and required every underground coal mine to install refuge alternatives to help prevent future fatalities of trapped miners in the event of a disaster. The following research was performed in response to NIOSH’s call for the investigation into new refuge alternatives. A 15 psi safe haven polycarbonate wall for use in underground coal mines was designed and modeled using finite element modeling in ANSYS Explicit Dynamics. The successful design was tested multiple times in both half-scale and small scale using a high explosive shock tube to determine the walls resistance to blast pressure. The safe haven wall design was modeled for an actual underground coal mine environment to determine any responses of the wall within a mine. A full scale design was fabricated and installed in an underground coal mine to determine any construction constraints and as a final step in proof of concept for the safe haven design.

Identiferoai:union.ndltd.org:uky.edu/oai:uknowledge.uky.edu:mng_etds-1002
Date01 January 2013
CreatorsMeyr, Rex Allen, Jr.
PublisherUKnowledge
Source SetsUniversity of Kentucky
Detected LanguageEnglish
Typetext
Formatapplication/pdf
SourceTheses and Dissertations--Mining Engineering

Page generated in 0.002 seconds