Previous issue date: 2016-07-07 / Esta dissertação apresenta a análise de eficiência energética predial feita no edifício do Ceamazon, laboratório de pesquisas vinculado à Universidade Federal do Pará. Para este estudo foi utilizada a metodologia prescritiva do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas – RTQ-C. A análise energética do RTQ-C envolve três parâmetros distintos: a envoltória da edificação, o sistema de iluminação artificial e o sistema de condicionamento de ar. O estudo dos dados de cada um destes sistemas fornece material para os cálculos necessários no método, que resultarão em um equivalente numérico para cada um, representando a eficiência de cada sistema. A análise desta dissertação foi efetuada principalmente nos sistemas de iluminação artificial e condicionamento de ar, visto que uma análise prévia dos dados de envoltória do prédio já havia coletado bons resultados. O objetivo primário da dissertação foi de enquadrar a edificação em questão no nível A de eficiência energética proposto pelo regulamento. Desta forma, foram feitas as adequações necessárias ao projeto do ponto de vista energético, especificamente nos sistemas de iluminação e refrigeração artificial, visando tanto a classificação máxima de acordo com o RTQ-C como também a economia de energia e consequentemente, a redução de custos. Assim sendo, serão apresentadas também propostas de inclusão de alternativas energéticas para o edifício, visando uma eficiência energética ainda maior, bem como análises de viabilidade econômica e simulações energéticas das alterações propostas ao projeto da edificação, através dos softwares RetScreen e EnergyPlus. / This dissertation presents the analysis of energy efficiency of the Ceamazon building, a research laboratory bounded to the Federal University of Pará. For this study it was utilized the prescriptive method of the “Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas – RTQ-C”. RTQ-C’s energy analysis involves three distinct parameters: the building envelope, the artificial illumination system and the air-conditioning system. The study of the characteristics of each one of these systems provides material for the necessary calculations of the method, which will result in a numeric equivalent for each one, representing the efficiency of each system. This dissertation’s analysis was done mainly at the artificial illumination system and the air-conditioning system, since one previous analysis of the building’s envelope had already collected good results. The primary goal of this dissertation was to fit the building studied in the level A of energy efficiency proposed by the regulation. Thus, adjustments were made to the project from the energetic point of view, specifically on the artificial illumination and air-conditioning systems, aiming not only the maximum classification according to RTQ-C but also energy savings and the consequent reduction of costs. Therefore, proposals of inclusion of energetic alternatives to the building will also be presented, aiming at a higher energy efficiency, as well as economic viability analysis and energetic simulations of the alterations proposed to the building project, utilizing the softwares RetScreen and EnergyPlus.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/7479 |
Date | 07 July 2016 |
Creators | RIBEIRO, Ricardo Bastos Piqueira |
Contributors | TOSTES, Maria Emília de Lima, BEZERRA, Ubiratan Holanda |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |