Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-05-04T19:00:50Z
No. of bitstreams: 1
ALANA KELLY XAVIER SANTOS CAMPOS – TESE (PPGEE) 2016.pdf: 5517354 bytes, checksum: 24306600f8b9a28a2d230c48b0811a3a (MD5) / Made available in DSpace on 2018-05-04T19:00:50Z (GMT). No. of bitstreams: 1
ALANA KELLY XAVIER SANTOS CAMPOS – TESE (PPGEE) 2016.pdf: 5517354 bytes, checksum: 24306600f8b9a28a2d230c48b0811a3a (MD5)
Previous issue date: 2016-10-21 / Capes / Um método de estimação fasorial é proposto para ser utilizado em relés digitais de proteção. Este método tem o objetivo de melhorar a característica de rejeição de componentes indesejáveis do sinal, que são introduzidas durante faltas e manobras nos sistemas elétricos de potência e podem comprometer o desempenho dos sistemas de proteção. São realizadas comparações entre o método proposto e outros quatro métodos de estimação fasorial, em relação às respostas no tempo e frequência. Para as comparações de resposta no tempo são utilizados sinais analíticos provenientes do MATrix LABoratory (MATLAB®) e sinais simulados provenientes do Alternative Transients Program (ATP). Um relé de distância foi implementado utilizando a linguagem MODELS do ATP para avaliar o desempenho do relé, utilizando o método proposto e demais métodos avaliados. A partir de alguns parâmetros usados para avaliar quantitativamente os métodos de estimação, observou-se que o método proposto apresenta bons resultados em termos de precisão e velocidade de convergência, com
resposta no tempo compatível com os demais métodos comumente utilizados. A resposta em frequência do método proposto se apresenta mais seletiva em relação aos demais, por apresentar menores lóbulos entre as harmônicas e uma banda de passagem mais estreita em torno da frequência fundamental. Outra vantagem do método proposto é que ele é de fácil programação e permite que os usuários alterem parâmetros de projeto de acordo com suas necessidades. / A phasor estimation method is proposed to be used in digital relays for power system protection. It aims to improve the characteristic of filtering out undesirable frequency components of signals, which are introduced during faults and switching events in electric power systems that may compromise the performance of the protection systems. Comparisons are made in relation to time response and frequency response for the proposed method and four phasor estimation methods. In relation to response time are used analytical signals from MATrix LABoratory (MATLAB®) and simulated signals from Alternative Transients Program (ATP). A distance relay was implemented by using the MODELS language in ATP to evaluate the performance of the relay. From some parameters used to evaluate the estimation methods, it was observed that the proposed method shows good results in terms of accuracy and convergence speed, with response time compatible with other methods. The frequency response of the proposed method appears to be more selective than those of the others methods because it presents lower lobes between the harmonics and a narrower pass
band around the fundamental frequency. Another advantage of the proposed method is that it can be easily programmed, allowing users to change design parameters according to their needs.
Identifer | oai:union.ndltd.org:IBICT/oai:localhost:riufcg/582 |
Date | 04 May 2018 |
Creators | CAMPOS, Alana Kelly Xavier Santos. |
Contributors | NEVES, Washington Luiz Araújo., FERNANDES JÚNIOR, Damásio., OLESKOVICZ, Mário., BOAVENTURA, Wallacy do Couto., BRITO, Nubia Silva Dantas., MOTA, Wellington Santos. |
Publisher | Universidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.003 seconds