Return to search

Melhoria nas forças restaurativas do equilíbrio do gerador de indução duplamente alimentado por meio de controle da tensão interna

Made available in DSpace on 2015-08-20T17:09:43Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-20. Added 1 bitstream(s) on 2015-08-20T17:26:33Z : No. of bitstreams: 1
000844247.pdf: 1768049 bytes, checksum: 97510557f0b1e78af085b05a10ac5b09 (MD5) Bitstreams deleted on 2015-08-28T16:09:04Z: 000844247_20190220.pdf,. Added 1 bitstream(s) on 2015-08-28T16:10:04Z : No. of bitstreams: 1
000844247_20190220.pdf: 658509 bytes, checksum: 397f7d1ef1d7c231d51be9a56af5eeff (MD5) / Propõe-se neste trabalho o desenvolvimento de um método analítico para o estudo da estabilidade dos geradores de indução duplamente alimentados (DFIG - Doubly Fed Induction Generator) com base no monitoramento da tensão interna E', uma vez que a degradação da mesma resulta na perda da capacidade de transmissão de potência. Deste modo, faz-se a análise do desempenho transitório da máquina pela observação da grandeza em que efetivamente reside a causa da instabilidade. Uma vez detectada a possível causa da instabilidade do gerador, um controle é proposto sobre a grandeza em que se desenvolve a instabilidade do gerador. A filosofia de controle desenvolvida baseia-se no controle da magnitude da tensão interna, contribuindo decisiva e positivamente para o aumento da capacidade de transmissão e, consequentemente, das forças restaurativas de equilíbrio do DFIG, resultando em melhoria da estabilidade do sistema. A validação da aplicação do controle via metodologia da tensão E' é realizada por meio de simulações computacionais em diversas contingências e com a ação conjunta do circuito crowbar. Evidencia-se que este método pode ser empregado para avaliação da criticidade do sistema em tempo real / This thesis proposes the development of an analytical method for stability analysis of the Doubly Fed Induction Generator (DFIG) based on the monitoring of the internal voltage E', since its degradation implies in decreasing of power transmission capacity and as consequence the reduction of transient performance. Thus, the analysis of the transient performance of the machine is performed by observing the quantity which is the effective cause of instability. Once detected the possible cause of the instability of the generator, is proposed a control of the quantity which originates the generator instability. The control philosophy is based on internal voltage magnitude control, contributing decisive and positively to the increase of transmission capacity and the DFIG equilibrium restorative forces, resulting improved stability of the system. The validation of the application of control methodology via voltage E' is proven through computational simulations in diverse contingencies, with and without action of crowbar circuit control. It is evident that this method can be used to evaluate the criticality of the system in real time

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/126413
Date20 February 2015
CreatorsZamperin, Joao Luiz Bergamo [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Colvara, Laurence Duarte [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format91 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1