Return to search

Estudo de controladores aplicados a inversores para UPS com operação ilhada

Made available in DSpace on 2014-12-02T11:16:45Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-12-18Bitstream added on 2014-12-02T11:21:42Z : No. of bitstreams: 1
000746210.pdf: 6245568 bytes, checksum: bdf740a9e0ec90838ebde8f31ea0e16e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta dissertação apresenta o projeto, simulação e ensaio dos protótipos da etapa de saída de uma Fonte de Alimentação Ininterrupta (UPS - Uninterruptible Power Supply) monofásica de tensão igual a 127V e trifásica com tensões 220/127V a 4 fios, ambas de frequência 60Hz e potência nominal igual a 1kVA para uso em operação ilhada. validação da metodologia de projeto foi realizada primeiramente em simulação, e depois, experimentalmente utilizando-se diferentes tipos de cargas tipicamente encontradas em instalações elétricas e diferentes tipos de controladores clássicos: PI (Controlador Proporcional Integral), Ressonante e composição dos dois. Os ensaios experimentais consistiram em duas etapas, regime e transitório, na primeira sendo avaliado o comportamento estático do conversor com parâmetros como valor eficaz (RMS - Root Mean Square) e a Distorção Harmônica Total (THD - Total Harmonic Ditortion) da tensão de saída e, na segunda, o comportamento frente à entrada e saída de cargas, evidenciando a estabilidade do controle. Nas duas etapas foram aplicados procedimentos normatizados de ensaios e os resultados foram comparados com os requisitos das normas aplicáveis a esse tipo de conversor. Como dispositivo de controle utilizou-se um Processador Digital de Sinais (DSP - Digital Signal Processing) de ponto fixo, responsável pelo cálculo do algoritmo de controle e leitura dos sinais de tensões e correntes do inversor; sendo avaliada sua capacidade de processamento frente à manutenção da qualidade e da frequencia do sinal de saída. O projeto aponta a necessidade do controle multimalhas, ou seja, controle da tensão mais corrente, devido à instabilidade criada em sua função de transferência ao alimentar as cargas não resistivas. Também é mostrada, em simulação, a possibilidade de trabalho da interface de potência do protótipo em outros propósitos: Retificar com Alto Fator de Potência (para recarga... / This dissertation presents the design, simulation and testing of the prototype os the stage of output of a UPS (Uninterruptible Power Supply) single-phase with voltage equal to 127V and three-phase with voltage equal to 127V and three-phase with voltage equal to 220/127V four-wired, both with 60Hz and nominal power of 1kVA to use in inslanded mode. The validation of the methodology of the project was realized first in simulation, and subsequently, experimentally using different kinds different kinds of loads typically found in electrical installations and, different kinds of classical controllers: PI (Proportional Integrative Controller), Resonant and composition of both. The testing has consisted of 2 stages: steady state and transitory state, in the first stage, it has been measured the RMS (Root Mean Square) value and THD (Total Harmonic Distortion) of the voltage of the output and, in the second stage, the behavior in relation to the loads step in and step out, highlighting the stability of the control. The standardized procedures of the test have been applied in the two stage and the results were compared to the requirements of the applicable standards to this kind of power converter. It has been used a fixed point DSP (Digital Signal Processing) as a device of control, which was responsible for the calculation of the control algorithm and for the signal sampling of voltages and currents of the inverter; being measured its processing capacity in relation to the conservation of power quality and the signal frequency of output. The project has indicated the necessary of the multi-loop control, i.e, voltage plus current controller, due to the instability generated in its transfer function when supplying non-resistive loads. It has been also demonstrated in simulation, the possibility of the power interface works in others functionalities: Rectifier with Power Factor Correction (to battery recharge), Current Source Inverter...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/110926
Date18 December 2013
CreatorsGuillardi Júnior, Hildo [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Serni, Paulo José Amaral [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format151 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0032 seconds