Influencia da geometria da junção soldada na resistencia a fadiga de ligas do sistema cobalto-cromo

Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T13:43:01Z (GMT). No. of bitstreams: 1
Cangiani_MarcosBlanco_M.pdf: 3225975 bytes, checksum: 9a3be646fff572577cec958bb3bfe690 (MD5)
Previous issue date: 1998 / Resumo: O propósito deste estudo foi investigar a resistência à fadiga das ligas do sistema Co-Cr (Dentorium e Degussa), submetidas ou não ao procedimento de soldagem convencional. Oitenta corpos-de-prova cilíndricos com 1,7 mm de diâmetro foram obtidos por fundição odontológica, utilizando maçarico à oxigênio e acetileno para cada tipo de liga. O procedimento de soldagem foi realizado em sessenta corpos-de prova de cada uma das ligas, sendo que vinte serviram de controle. A soldagem foi efetuada com uma liga à base de Co-Cr utilizando um maçarico à oxigênio e gás (G.L.P.). Uma distância de 0,3 mm foi padronizada entre as extremidades dos três tipos de preparo (topo a topo, chanfro de 30° e ponta de lápis) a serem soldadas. O
ensaio de resistência à fadiga foi realizado numa máquina de cargas cíclicas AMSLER (Alfred J. Amsler & Co.), calibrada com carga constante de tração de 1 kgf, com os corpos-de-prova solicitados à flexão por ciclo oscilatório de 2° para cada lado. Após a fratura, o número de ciclos foi registrado e a superfície de fratura
analisada sob M.EV.. Os resultados foram estatisticamente analisados usando a análise ,de variância e o teste de Tukey, nos quais verificamos que: 1 - Para a liga Dentorium, os três tipos de preparo (com solda) apresentaram valores de resistência estatisticamente semelhante entre si, porém, foram estatisticamente inferiores ao controle (sem solda); 2 - Para a liga Degussa, os preparos tipo ponta de lápis e topo a topo (com solda) mostraram valores de resistência à fadiga estatisticamente semelhantes entre si, porém, estatisticamente inferiores ao controle (sem solda) e preparo em chanfro de 30°. Nenhuma diferença estatística foi encontrada entre o controle e o preparo em chanfro de 30°; 3 -. a liga Dentorium apresentou valores de
resistência à fadiga estatisticamente superior à liga Degussa, quando a solda foi efetuada no preparo tipo ponta de lápis. Nenhuma diferença estatística foi observada para o controle e os tipos de preparos em chanfro de 30° e topo a topo / Abstract: The purpose of this study was to investigate the fatigue stength of the system Co-Cr (Dentorium and Degussa), submitted or not to the procedure conventional soldering. Cylindrical eighty specimens with 1,7 mm in diameter were casted utilizing oxi-acetilene torch for each alloys kind. The soldering procedure was
realizated in sixty specimens of each alloy and twenty were control. the soldering were obtained by Co-Cr welding rods and gas-oxygen torch. the solder gap selected was 0.3 mm for each prepared (top to top, chamfer 30° and pencil point). The fatigue strength was conducted in a AMSLER (alfred J. Amsler & Co. - Shaffhausen
Schaweis - Switzerland) fatig~e testing machine and the specimens were sujected to a tensile load of 1 kg, and a ciclic stress amplitude of 2°. After failure, the cycles were registered and the fracture surface was examined with (S.E.M.). The results were statistically analysed using a Mann-Whitney. The results of this study indicated that: 1 - For the Dentorium alloy the three types of prepare (with solder) presented- values of strength statistically similar to each other but inferior statistically than control (without solder); 2 - For the Degu'ssa
alloy, the type of prepared pencil point and top to top (with solder) showed the similar results statistically, but inferior statistically to the control (without solder) in chamfer of 30°. No statistical difference wás found between the control and prepared in chamfer of 30°; 3 - The Dentorium alloy presented resistance values of fatigue superior statistically the degussa alloy, when it solde r was made in prepare pencil point. No statistical difference was observed for the control and ty pes of prepared in chamfer 30° and top to topo / Mestrado / Materiais Dentarios / Mestre em Ciências

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289574
Date23 April 1998
CreatorsCangiani, Marcos Blanco
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Correr Sobrinho, Lourenço, 1960-
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Ciências
Source SetsIBICT Brazilian ETDs
LanguagePortuguese