Return to search

Simple Models for Estimating the Rotational Stiffness of Steel Column-to-Footing Connections

Despite the crucial role they play in transferring loads from the superstructure to the foundation, steel column-to-footing connections have received little attention in research. Though shallow embedded connections are typically characterized as pinned, studies have shown that they exhibit significant rotational stiffness. The objective of this thesis is to quantify the rotational stiffness of such connections. A method named the continuum model is developed by which the rotational stiffness of embedded connections may be calculated. Outputs from this model are compared with experimental data on steel connections embedded in concrete. The continuum model is shown to be capable of reasonably predicting the rotational stiffness of such connections. Results from the model were consistent with those of previous experimental studies that showed that embedment lengths greater than twice the column depth fail to significantly increase stiffness. Plots of rotational stiffness vs. embedment length developed from the continuum model are provided such that rotational stiffness may be calculated for any wide flange shape at any embedment length. Simplified equations provide a simpler way for engineers to estimate the same information.

Identiferoai:union.ndltd.org:BGMYU2/oai:scholarsarchive.byu.edu:etd-6821
Date01 March 2016
CreatorsTryon, Joshua Edwin
PublisherBYU ScholarsArchive
Source SetsBrigham Young University
Detected LanguageEnglish
Typetext
Formatapplication/pdf
SourceAll Theses and Dissertations
Rightshttp://lib.byu.edu/about/copyright/

Page generated in 0.0019 seconds