The possibility to save energy in synchronous machines operation by dismissing d-axis damping bars and surrogating them with active excitation current control in sectored field winding is proved. In particular a way to recover the energy of rotor oscillations during power regulation is shown by means of a studycase generator whereas a self-starting machine is analytically and numerically designed in view of its next construction and test. Principal design requirements and limits for both applications are presented and discussed.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:uu-353669 |
Date | January 2018 |
Creators | Felicetti, Roberto |
Publisher | Uppsala universitet, Institutionen för teknikvetenskaper |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, info:eu-repo/semantics/bachelorThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Relation | Uppsala Dissertations from the Faculty of Science and Technology, 1104-2516, TVE-MFE ; 18004 |
Page generated in 0.002 seconds