Return to search

Rozměření signálu EKG pro analýzu TWA / Measurement of ECG signal for TWA analysis

The thesis deals with possibilities of using wavelet transform in the field of surface electrocardiogram (ECG) signals denoising and ECG signals measuring. Several algorithms have been used to detect and estimate T-wave alternans (TWA), such as spectral method (SM), Poincaré Mapping (PM) or correlation method (CM). T-wave alternans, also called repolarization alternans, is a phenomenon appearing in the electrocardiogram as a consistent fluctuation in the repolarization morphology on every-other-beat basis. Electrical TWA has been recognized as a marker of electrical instability, and has been shown to be related with patients at increased risk for ventricular arrhytmias. Presence of TWA has been reported in a wide range of clinical and experimental situations including long QT syndrome, myocardial infarction, angina pectoris, acute ischemia, etc. Projected methods of detection TWA are realized in Matlab software, and they are experimentally verified on real ECG signals from the European ST-T Database.

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:217734
Date January 2008
CreatorsŘezáč, Petr
ContributorsVítek, Martin, Kozumplík, Jiří
PublisherVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess

Page generated in 0.002 seconds