Return to search

Study and Design of a Sensor System for the Detection of Illicit Discharges in Sewers and Water Bodies

[ES] El uso del agua en nuestra sociedad es de gran importancia. Cuando el agua se utiliza y deja de ser útil, se convierte en agua residual. Esta contiene sustancias que ponen en peligro la salud humana y los ecosistemas. Para reducir el daño ambiental existen las depuradoras que reducen los niveles de contaminación del agua. En las industrias, las depuradoras se encargan de reducir la carga contaminante del agua para su vertido en alcantarillado o al medio ambiente. La presencia de vertidos ilegales y desbordamientos en el alcantarillado suponen una amenaza para las masas de agua. Estos provocan una bajada en el rendimiento de las depuradoras. En muchos casos no es posible detectar al responsable de estos. Lo que hace que estos queden impunes violando el principio ambiental de quien contamina paga.
Para solucionar este problema se propone un sistema de bajo coste para la monitorización de parámetros del agua para detectar problemas en los alcantarillados dentro de las ciudades inteligentes (Smart cities). La hipótesis de trabajo es que ante la presencia de un vertido ciertos parámetros del agua cambiarán lo suficiente como para que pueda ser detectado. Al detectarse el sitio del vertido se podrá acudir rápidamente al lugar a fin de cesar el vertido además de tomar las acciones legales pertinentes.
Primero, hemos estudiado otros sistemas para monitorizar el alcantarillado Con esta información se determina los parámetros más interesantes y que pueden ser medidos con un bajo coste son temperatura, conductividad, turbidez, nivel de agua y aceite. Además, de sensores de lluvia para el alcantarillado pluvial.
Para la monitorización de estos parámetros se escogen sensores comerciales de bajo coste para los parámetros de temperatura, nivel y lluvia. Para los otros parámetros se decidió desarrollar nuestros propios sensores. Para ello se utilizó sensores del tipo inductivos para la conductividad y sensores ópticos para el control de la turbidez y el aceite.
Respecto a los sensores inductivos, se ha determinado que existen interferencias de los sólidos y del nivel de agua en la respuesta del sensor. Sin embargo, en el caso de los sólidos esta interferencia es pequeña en la concentración de solidos que existe en el alcantarillado, siendo esta de 0.078 V/gramo. En cambio, la cantidad de agua sí que afecta a la respuesta de la bobina de forma significativa.
Respecto a la turbidez se han realizado dos prototipos diferentes. Un prototipo ha sido desarrollado para cuerpos de agua y el otro para el alcantarillado. El prototipo desarrollado para cuerpos de agua es capaz de determinar el porcentaje de algas que existen en el agua conociendo la cantidad de solidos en el agua. Para la detección del aceite hemos desarrollado otro sensor óptico. Hemos hecho pruebas a distintas alturas de agua. Viendo que éramos capaces de identificar si el aceite provenía de un motor gasolina o de un motor diésel, y en el caso de aceite usado por un motor de gasolina éramos capaces de cuantificarlo. Por último, respecto a nuestro sistema hemos analizado mediante simulaciones la utilidad de un sensor de nivel en el alcantarillado. Hemos detectado que en el caso de alcantarillado pluvial este sí que puede ser útil. Además, hemos testeado en una tubería el sensor inductivo y el de aceite con diferentes concentraciones de sal y aceite para ver su funcionamiento. El coste estimado de cada uno de los nodos sensores es de 120 €.
Los sensores desarrollados pueden ser utilizados en otros ambientes. Estos trabajos son: (I) el uso de bobinas para la monitorización de la humedad del suelo, (II) el uso de sensores ópticos para detectar gasóleo B en vehículos (III) el uso de sensores y tecnología de bioabsorción en canales de riego afectados por aguas residuales y (IV) el uso del sensor de aceite en canales de riego. / [CA] The use of water in our society is of great importance. Once the water has been used, it becomes wastewater. These waters contain substances that endanger human health and ecosystems. To reduce environmental damage, there are treatment plants that treat these waters to reduce their levels of contamination. Industrial treatment plants are responsible for reducing the contaminant load of the water so that it can be discharged into the public sewer system or into the environment.
The presence of illegal discharges and overflows in the sewage system pose a threat to water bodies. These discharges can cause a drop in the performance of the treatment plant, which will cause an effluent of poorer quality. In many cases, it is not possible to detect who is responsible for the spills. What makes these go unpunished violating the environmental principle of that whoever pollutes pays.
To solve this problem, a low-cost system for monitoring water parameters to detect problems in sewers within the context of smart cities is proposed. Our working hypothesis is that in the presence of a discharge, the concentration of specific water parameters will change enough to be detected. When the site of the spill is detected, it will be possible to quickly go to the place in order to stop the spill in addition to taking the necessary legal actions against the person who is carrying out the spill.
First, we have compiled information about other systems to monitor sewage, With this information, we have determined that the most exciting parameters that we are able to measure at a low cost are temperature, conductivity, turbidity, water and oil level. In addition, the use of rain sensors for storm sewers is included.
To monitor these parameters, low-cost commercial sensors are chosen to monitor temperature, level and rainfall. For the other parameters, we decided to develop our own sensors. We decided to use inductive type sensors for conductivity and optical sensors for turbidity and oil control.
Regarding the inductive sensors, we have determined that there are interferences of the solids and the water level in the response of the sensor.. However, in the case of solids, this interference is minor in the concentration of solids that exists in the sewage system (0.078 V/gram). On the other hand, the amount of water does affect the response of the coil significantly. Therefore, the sensor must be submerged.
Regarding turbidity, we have made two different prototypes. One prototype has been developed for bodies of water and the other for sewage. The prototype developed for bodies of water is capable of determining the percentage of algae that exist in the water, knowing the amount of solids in the water.
For oil detection, we have developed another optical sensor. We have done tests at different heights of water. Seeing that we were able to identify if the oil came from a gasoline engine or a Diesel engine, and in the case of oil used by a gasoline engine, we were able to quantify it.
Finally, regarding our system, we have analyzed through simulations the usefulness of a level sensor in the sewage system. We have detected that in the case of storm sewage, this can be useful. In addition, we have tested the inductive sensor and the oil sensor in a pipe with different concentrations of salt and oil to see how they work. The estimated cost of each sensor node is 120 €.
The developed sensors can be used in other environments. For this reason, we show other works carried out during the thesis period with the developed sensors. These works are: (I) The use of coils for soil moisture monitoring, (II) the use of optical sensors to detect diesel B in vehicles, (III) the use of sensors and bioabsorption technology in irrigation canals affected by wastewater, and (IV) the use of the oil sensor in irrigation channels. / [EN] L'ús de l'aigua a la nostra societat és de gran importància. Un cop l'aigua s'ha utilitzat i deixa de ser útil per a l'activitat, aquesta es converteix en aigües residuals. Aquestes aigües contenen substàncies que posen en perill la salut humana i dels ecosistemes. Per reduir el danys mediambientals existeixen les depuradores que tracten aquestes aigües per reduir contaminació la seua carrega contaminants.. Les depuradores industrials s'encarreguen de reduir la càrrega contaminant de l'aigua perquè es pugui abocar al clavegueram públic o al medi ambient.
La presència d'abocaments d'aigua il·legals i els desbordaments al clavegueram suposen una amenaça per a les masses d'aigua. Aquests abocaments poden provocar una baixada en el rendiment de la depuradora. En molts casos no és possible detectar el responsable dels abocaments. Això fa que aquests queden impunes violant el principi ambiental de qui contamina paga.
Per solucionar aquest problema es proposa un sistema de baix cost per a la monitorització de l'aigua per detectar problemes als claveguerams en les ciutats intel·ligents (Smart cities). La hipòtesi de treball consisteix que davant la presència d'un abocament la concentració de certs paràmetres de l'aigua canviarà lo suficient perquè es pugui detectar. En detectar-se el lloc de l'abocament es podrà acudir ràpidament al lloc per cessar l'abocament a més de prendre les accions legals que siguin necessàries contra la persona que està realitzat l'abocament.
Primer, hem estudiat altres sistemes per monitoritzar el clavegueram. Amb aquesta informació s'ha determinat que els paràmetres més interessants i que poden ser mesurats amb un baix cost són temperatura, conductivitat, terbolesa, nivell d'aigua i oli. A més, l'ús de sensors de pluja per al clavegueram de pluvials.
Per monitoritzar aquests paràmetres s'escullen sensors comercials de baix cost per ala temperatura, el nivell i la pluja. Per als altres paràmetres, es decideix desenvolupar els nostres propis sensors. Decidim utilitzar sensors del tipus inductius per a la conductivitat i sensors òptics per al control de la terbolesa i l'oli.
Pel que fa als sensors inductius, s'ha determinat que hi ha interferències dels sòlids i del nivell d'aigua en la resposta del sensor. No obstant això, en el cas dels sòlids aquesta interferència és petita en la concentració de sòlids que hi ha al clavegueram, aquesta és de 0.078 V/gram. En canvi, la quantitat d'aigua sí que afecta la resposta de la bobina de manera significativa.
Pel que fa a la terbolesa s'han realitzat dos prototips diferents. Un prototip ha estat desenvolupat per a cossos d'aigua i l'altre per al clavegueram. El prototip desenvolupat per a cossos d'aigua és capaç de determinar el percentatge d'algues que hi ha a l'aigua coneixent la quantitat de sòlids a l'aigua.
Per detectar l'oli hem desenvolupat un altre sensor òptic. Hem fet proves a diferents alçades d'aigua. Veient que érem capaços d'identificar si l'oli provenia d'un motor benzina o d'un motor dièsel, i en el cas d'oli usat per un motor de benzina érem capaços de quantificar-lo.
Finalment, respecte al nostre sistema hem analitzat mitjançant simulacions la utilitat d'un sensor de nivell al clavegueram. Hem detectat que en el cas de clavegueram pluvial aquest sí que pot ser útil. A més, hem testejat en una canonada el sensor inductiu i el d'oli amb diferents concentracions de sal i oli per veure'n el funcionament.
El cost estimat de cadascun dels nodes sensors és de 120 €.
Els sensors desenvolupats poden ser utilitzats en altres ambients.. Aquests treballs són: (I) L'ús de bobines per a la monitorització de la humitat del sòl, (II) l'ús de sensors òptics per detectar gasoil B (sota impostos) en vehicles no autoritzats, (III) l'ús de sensors i tecnologia de bioabsorció en canals de reg afectats per aigües residuals, (IV) l'ús del sensor d'oli a canals de reg. / Rocher Morant, J. (2023). Study and Design of a Sensor System for the Detection of Illicit Discharges in Sewers and Water Bodies [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/192823

Identiferoai:union.ndltd.org:upv.es/oai:riunet.upv.es:10251/192823
Date18 April 2023
CreatorsRocher Morant, Javier
ContributorsLloret Mauri, Jaime, Mengual Cuquerella, Jesús, Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient
PublisherUniversitat Politècnica de València
Source SetsUniversitat Politècnica de València
LanguageEnglish
Detected LanguageSpanish
Typeinfo:eu-repo/semantics/doctoralThesis, info:eu-repo/semantics/acceptedVersion
Rightshttp://rightsstatements.org/vocab/InC/1.0/, info:eu-repo/semantics/openAccess

Page generated in 0.0034 seconds