Return to search

Avaliação radiográfica, biomecânica e microscópica de enxerto ósseo xenogênico associado a implantes de titânio em mandíbula de coelhos / Radiographic, biomechanical and microscopic evaluation of xenogenic bone graft associated to titanium implants in rabbits mandible

O propósito deste trabalho foi avaliar a interação de matriz óssea bovina inorgânica, (Gen-ox®) como material de enxerto e implantes de titânio em mandíbula de coelhos. A amostra constituiu-se de 32 coelhos da raça Botucatu de aproximadamente 4kg. Os incisivos inferiores destes animais foram extraídos e foi realizada um defeito de aproximadamente 4mm de diâmetro. Um dos lados foi mantido apenas com coágulo (grupo controle) e o outro lado (grupo experimental) recebeu o enxerto do material proposto. Após 60 dias foram instalados implantes bilateralmente na região do defeito. Os animais foram eutanaziados imediatamente após a instalação dos implantes e após 1, 2 e 6 meses (n=6) para o grupo microscópico a após 2 e 6 meses para o grupo do teste biomecânico (n=4). A análise constituiu de medidas da distância da crista óssea alveolar à plataforma do implante, da densidade radiográfica em valores de pixel ma região do alvéolo, de teste biomecânico de torque de remoção e microscópico através de medidas de contato osso-implante (BIC) (em µm e %) e área de osso (em µm2 e %). Os resultados demonstraram que não houve diferenças significantes nem durante o tempo e nem entre os grupos na analise de distancia entre crista óssea alveolar e plataforma do implante. Na medida de densidade óssea, não houve variação significante ao longo do tempo, mas houve diferença estatisticamente significante entre os grupos, sendo maior no grupo experimental. Para o teste biomecânico também não houve variação significante do torque de remoção ao longo do tempo e nem houve diferença significante entre os grupos. Na análise de contato osso implante (BIC) não houve variação significante ao longo do tempo, mas houve diferença estatisticamente significante entre os grupos, sendo maior no grupo experimental e houve interação entre tempos e grupos. E com relação a medida de área de osso não houve diferenças significantes nem durante o tempo e nem entre os grupos controle e experimental nos períodos analisados. Os resultados sugerem que o material foi bem aceito na região e teve comportamento semelhante ao coágulo em contato com a superfície do implante. / The aim of this study was to evaluate the interaction of an inorganic bovine bone matrix (Gen-ox®) as bone graft and titanium implants in rabbits mandible. Thirty-two Botucatu rabbits weighting about 4kg were used on this experiment. The mandible incisives were extracted and a defect of 4 mm of diameter was performed. One socket and defect was filled with experimental material. The opposite site was left to heal naturally and served as control. After 60 days, the implants were installed on the defect region. The animals were killed immediately after the implant installation and after 1, 2 and 6 months. Vertical bone height, bone density, biomechanical test, bone implant contact (BIC) and bone area near to implant threads were evaluated. The results showed that there was no significant differences on the distance between the alveolar bone crest to the implant platform (vertical bone height) along the time, neither between groups. On the bone density (pixel value) there was no significant difference along the time, but there was significant difference between groups, being the experimental group higher. For the biomechanical test there was no significant difference along the time, neither between groups. There was no significant differences on the bone implant contact (BIC) measures along the time, but there was significant difference between groups, being the experimental groups higher and there was interaction between time and groups. On bone area evaluation, there was no significant difference along the time, neither between the groups during the analyzed time. The graft behavior observed by the authors was similar to that of the control group, suggesting high acceptance of the material as graft option associated to titanium implants.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-30062009-160911
Date08 June 2009
CreatorsEtiene de Andrade Munhoz
ContributorsOsny Ferreira Júnior, Ana Lúcia Pompéia Fraga de Almeida, Edevaldo Tadeu Camarini, Paulo Sergio Perri de Carvalho, Maria Lucia Rubo de Rezende
PublisherUniversidade de São Paulo, Odontologia (Estomatologia e Biologia Oral), USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds