Return to search

Anastomose mecanica em reto extraperitoneal : (duas tecnicas de reconstrução) : estudo experimental comparativo em caes

Orientador: Mario Mantovani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-20T07:49:32Z (GMT). No. of bitstreams: 1
Cordeiro_Fernando_D.pdf: 2068361 bytes, checksum: 97d91be5ff1e0751980ea396735baf24 (MD5)
Previous issue date: 1995 / Resumo: Os problemas resultantes das anastomoses no reto abaixo da reflexão peritoneal continuam
sendo tema de discussões. Com o desenvolvimento de novas técnicas pode-se estender a ressecção anterior aos segmentos retais mais baixos com preservação do mecanismo esfincteriano, porém a segurança destes procedimentos está por ser estabelecida. Este estudo comparativo randomizado entre duas técnicas de anastomose mecânica no reto de cães, abaixo da reflexão peritoneal, permitiu a elaboração deste trabalho. Para isso, submeteram-se vinte animais à retocolectomia, efetuando-se a reconstrução do trânsito intestinal por dois métodos: em um grupo de dez cães, pela sutura mecânica circular de maneira término-terminal dita direta e, em outro, pela sutura mecânica circular, através do fechamento linear do coto retal de maneira término lateral terminalizada dita dupla. As suturas foram avaliadas aos quinze dias do pós-operatório, com atenção ao estudo macro e microscópico das anastomoses e das complicações a elas atribuíveis principalmente à estenose. A análise desse estudo permitiu concluir: (1) a avaliação macroscópica . da cicatrização, tanto interna quanto externamente, não revelou diferença significativa entre as duas técnicas de anastomose; (2).a avaliação microscópica na anastomose, ao décimo quinto dia do pós-operatório, mostrou não haver diferença estatísticamente
significativa entre os dois grupos; (3) a prevalência de estenose foi baixa em ambas as técnicas de anastomose mecânica, sem diferença significativa, não havendo relação entre um menor calibre do aparelho de sutura automática e um maior índice de estenose; (4) a ausência de diferença de resistência tênsil, de deiscência, fistula e hemorragia na linha de anastomose e de mortalidade de ambos os grupos revelou que ambas as técnicas de anastomose mecânica se equivaleram, e (5) as anastomoses mecânicas direta e dupla foram técnicas válidas e seguras nas cirurgias no reto extraperitoneal de cães / Abstract:The problems resulting from the anastomosis in the rectum below the peritoneal reflexion keep on being the subject of discussions. With the development of new techniques the anterior resection can be extend to the lower rectal segments preserving the sphincterial mechanism. However, the security of these procedures is not yet a facto It was the comparative randomized study between two di.fferent techniques of mechanical anastomosis in the dogs 'rectum below the peritoneal reflexion that gave orig;n to this research.In this study twenty dogs underwent proctocolectomy, using two different methods to reconstruct the intestinal transit: the circular mechanical suture in a terminus-terminal way called "single stapling technique" (SST) in a group of ten dogs; and the circular mechanical suture through the linear closing of the rectal stump in a terminus-lateral way called "double stapling technique" (DST) in another group. The sutures were evaluated on the fifteenth postoperative day, paying special aUention to the macro and microscopic study of the anastomosis and the complications auributed to them, special/y the stenosis. The ana/ysis of this study led us to the following conclusions: 1) the macroscopic evaluation of the healing, both internal and external did not show any significant di.fference between the two techniques of anastomosis; 2) the microscopic evaluation of the anastomosis on the fifteenth postoperative day showed no important statistical difference between the two groups; 3) the prevalence of stenosis was small in both techniques of mechanical anastomosis, with no significative difference, showing no relation between a smaller diameter of the automatic anastomosis instrument and a greater incidence of stenosis; 4) the absence of tensi/e resistance difference, of dehiscence, fistula or hemorrhage difference in the anastomotic line and also no mortality difference in both groups showed that both techniques of mechanical anastomosis were equivalent, and 5) the mechanical anastomosis either "single" (SST) or "double" (DST) were valid and safe techniques for low rectum anastomosis / Doutorado / Cirurgia / Doutor em Cirurgia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311253
Date20 July 2018
CreatorsCordeiro, Fernando
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mantovani, Mário, 1940-, Mantovani, Mario
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format108f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.1871 seconds