Extragalactic charged particles, each with energies rising up to and beyond 1 Joule, have been studied for almost a century. Yet, no precise evidence have proven to show where they might originate from as their energy levels rise above the current familiar acceleration sources in outer space. The highly energetic particles have been given the name Ultra-High Energy Cosmic Rays (UHECR) and investigations of particle properties such as primary energy, mass composition and direction can be made through indirect measurements of the interaction between the UHECR and Earth's atmosphere. The considered interaction induces an Extensive Air Shower (EAS) which emits fluorescent light in the Ultraviolet (UV) range. The probability of detecting such events is, however, as low as a few particles per km2 per century. Making observations more sufficient therefore requires larger detection volumes. By introducing the Mini-EUSO instrument, a telescope of which the main purpose is to measure the UV-light radiated from the Earth in the wavelength range of 300-400 nm, allows just for this. To be accommodating the International Space Station and targeting Earth in the nadir direction, the Mini-EUSO instrument will allow for a higher exposure to the interactions than what is currently available. The use of two Fresnel lenses provides the instrument with a large field of view (±22o) and the detections are made through multiple photomultiplier tubes. The scope of this thesis is to evaluate the main detector of the Mini-EUSO instrument (i.e. the UV-detector) through ground-based tests. The procedures involved in the evaluation have consisted of; validating the statistical distributions of the signals, implementing dark field and flat field calibrations, and radiations measurements with three kinds of radiation sources. The data from the tests were provided during two periods and the visualization was made by adapting an already existing piece of code, using Python and ROOT Cern, to perform step by step procedures such that all operations are overlooked properly. The analysis showed that the implementation of the dark field and flat field procedures improved the original image significantly. It also showed that both the lower and higher photon count values in a pixel indeed gave the expected statistical behaviours, with a Poissonian distribution for low values and a Gaussian distribution for higher values. The flat fielding screen did however show unknown fluctuations in the emitted light and further tests have to be implemented to assure its functionality. Under proper covering, almost no dark current was found, however, observation tests showed that the borders of the Multi-Anode Photomultiplier Tubes (MAPMTs) gave higher photon count values than the center part even when they were emitted with Lambertian light.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:ltu-68250 |
Date | January 2018 |
Creators | Lukanovic, Matej |
Publisher | Luleå tekniska universitet, Rymdteknik |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, info:eu-repo/semantics/bachelorThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0021 seconds