ITC/USA 2009 Conference Proceedings / The Forty-Fifth Annual International Telemetering Conference and Technical Exhibition / October 26-29, 2009 / Riviera Hotel & Convention Center, Las Vegas, Nevada / In this project, a telemetry system is implemented to save firefighters from potential danger in their working environment. Each Firefighter has a "node" or "unit" attached to them which contains temperature, oxygen, and carbon-monoxide sensors, and a transceiver. Each node constantly transmits data collected by the sensors to a central "base station." The base station consists of a laptop which is monitored by the Fire Chief at a safe distance from the scene, and it displays gas levels. The base station monitors the sensor readings, and sets off an alarm locally and also at the node if a reading has reached a predetermined critical value.
Identifer | oai:union.ndltd.org:arizona.edu/oai:arizona.openrepository.com:10150/606108 |
Date | 10 1900 |
Creators | Uprety, Sandip, Caglio, Joseph, Ho, Michelle, Chio, Chi Hou, Mckeefery, Stephanie, Goh, Jae Hyok |
Contributors | Marcellin, Michael, Melde, Kathleen, University of Arizona |
Publisher | International Foundation for Telemetering |
Source Sets | University of Arizona |
Language | en_US |
Detected Language | English |
Type | text, Proceedings |
Rights | Copyright © held by the author; distribution rights International Foundation for Telemetering |
Relation | http://www.telemetry.org/ |
Page generated in 0.002 seconds