Thermoelastic stress analysis techniques for mixed mode fracture and stochastic fatigue of composite materials

This study develops new quantitative thermoelastic stress analysis (TSA) techniques for fracture and fatigue damage analysis of composite materials.

The first part deals with the thermo-mechanical derivation of two quantitative TSA techniques applied to orthotropic composites with and without a transversely-isotropic surface coating layer. The new TSA test procedures are derived in order to relate the thermal infrared (IR) images with the sum of in-plane strains multiplied by two newly defined material constants that can be experimentally pre-calibrated. Experiments are performed to verify the TSA methods with finite element (FE) numerical results along with available anisotropic elasticity solution.

The second part of this study applies the quantitative TSA techniques together with the Lekhnitskii's general anisotropic elasticity solution to calculate mixed-mode stress intensity factors (SIFs) in cracked composite materials. The cracked composite coupons are subjected to off-axis loadings with respect to four different material angles in order to generate mixed-mode SIFs. A least-squares method is used to correlate the sum of in-plane strains from the elasticity solution with the measured TSA test results. The mode-I and mode-II SIFs are determined from eccentrically loaded single-edge-notch tension (ESE(T)) composite specimens. The FE models and virtual crack closure technique (VCCT) are utilized for comparisons.

In the third part, a new stochastic model is proposed to generate S-N curves accounting for the variability of the fatigue process. This cumulative damage Markov chain model (MCM) requires a limited number of fatigue tests for calibrating the probability transition matrix (PTM) in the Markov chain model and mean fatigue cycles to failure from experiments. In order to construct the MCM stochastic S-N curve, an iterative procedure is required to predict the mean cycles to failure. Fatigue tests are conducted in this study to demonstrate the MCM method. Twenty-one open-hole S2-glass laminates are fatigue-cycled at two different stress levels. The coupon overall stiffness and surface-ply TSA damage area have been used as two damage metrics. The MCM can satisfactorily describe the overall fatigue damage evolution for a limited number of coupons (less than 6) subjected to a given specific stress level. The stochastic S-N curve can be constructed using at least two sets of fatigue tests under different stress levels. Three available fatigue tests for different E-glass laminates from the literature are also investigated using the proposed MCM approach. The results show the MCM method can provide the stochastic S-N curves for different composite systems and a wide range of fatigue cycles.

Identiferoai:union.ndltd.org:GATECH/oai:smartech.gatech.edu:1853/24818
Date05 May 2008
CreatorsWei, Bo-Siou
PublisherGeorgia Institute of Technology
Source SetsGeorgia Tech Electronic Thesis and Dissertation Archive
Detected LanguageEnglish
TypeDissertation

Page generated in 0.002 seconds