Return to search

A New High Voltage Partial Discharge Indicator System

In this thesis work, a new partial discharge magnitude indicator with LCD display was designed. This system was implemented in high voltage partial discharge detection and measurement systems. AVRISP In-System programmer is used to program the microprocessors used inside the display unit. The time resolution of the system (one pixel of the display unit) is 4 microseconds. The unit is capable of counting the number of impulses of the input voltage that is coming from the high voltage system within user selectable time intervals. The changeable values of the time intervals are 2, 4, 6, 8 and 10 seconds. It is also capable of showing the maximum value of the impulses in a given time interval. This maximum value is a number changing between 0 and 256. By calibration of the system, it was possible to indicate the discharge magnitudes in picocoulombs.

Identiferoai:union.ndltd.org:METU/oai:etd.lib.metu.edu.tr:http://etd.lib.metu.edu.tr/upload/2/12607263/index.pdf
Date01 June 2006
CreatorsGul, Ibrahim Oguz
ContributorsHizal, Mirzahan
PublisherMETU
Source SetsMiddle East Technical Univ.
LanguageEnglish
Detected LanguageEnglish
TypeM.S. Thesis
Formattext/pdf
RightsTo liberate the content for METU campus

Page generated in 0.0095 seconds