Return to search

AdsorÃÃo de metais tÃxicos de efluente aquoso usando pà da casca de coco verde tratado / Adsorption of toxic metals from aqueous effluents using green coconut shell powder treated

Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Os resÃduos sÃlidos agroindustriais sÃo bastante estudados devido a sua abundÃncia e baixo custo para a recuperaÃÃo de efluentes industriais utilizando processos de adsorÃÃo. Neste trabalho utilizou-se o pà da casca de coco verde como adsorvente para remoÃÃo de metais pesados de efluentes aquosos produzidos por indÃstrias de eletrodeposiÃÃo localizadas em Juazeiro do Norte (CearÃ-Brasil). Sistemas de adsorÃÃo em batelada e coluna foram estudados. Na primeira etapa deste trabalho foram investigados o tratamento quÃmico, o efeito da granulometria, o efeito da concentraÃÃo do adsorvente e o efeito do pH. Os resultados mostraram que o tratamento aplicado no pà da casca de coco verde com NaOH 0,1mol.L-/3h foi mais eficiente. Este material foi usado para o estudo de adsorÃÃo dos metais com as seguintes caracterÃsticas: faixa de granulometria de 60-99 mesh, concentraÃÃo de 40g/L e pH 5,0. O estudo de cinÃtica indicou que o equilÃbrio de adsorÃÃo multielementar foi atingido em 5 minutos (pH 5,0) e segue cinÃtica de pseudo-segunda ordem. As capacidades mÃximas de adsorÃÃo observadas nos estudos de equilÃbrio para um sistema multielementar foram: 7,89; 1,72; 3,24; 13,26 e 5,09 mg/g para Pb+2; Ni+2; Cd+2; Zn+2 e Cu+2, respectivamente. Na segunda etapa da pesquisa foram realizados experimentos para otimizaÃÃo das condiÃÃes operacionais da coluna. Os resultados mostraram que uma velocidade de fluxo de 2mL/min e uma altura de 10cm do leito aumentaram o percentual de remoÃÃo para todos os metais tÃxicos estudados. As curvas de ruptura investigadas para um sistema multielementar indicaram que a ordem das capacidades de adsorÃÃo foi a seguinte: Cu+2 > Pb+2 > Cd+2 > Zn+2 > Ni+2. A aplicabilidade dos estudos de coluna numa amostra real oriunda de empresas de galvanoplastia contendo: Ni+2, Zn+2 e Cu+2 mostraram que a remoÃÃo dos Ãons tÃxicos aumenta quando o pH da soluÃÃo à 5,0. A dessorÃÃo dos Ãons metÃlicos, retidos na coluna, foi eficiente usando HNO3 1,0mol.L- como eluente. Os ensaios de reciclagem da coluna mostraram que o adsorvente pode ser utilizado apenas num ciclo. / The solid agroindustry residues are most studied, due its abundance and low cost for recovery of wastewater industry using process of adsorption. In this work was used the green coconut shell powder as adsorbent for the heavy metals removal from wastewater aqueous produced for electroplating industries localized in Juazeiro do Norte (Ceara-Brazil). Adsorption systems in batch and column were studied. In the first step of this work was investigated the chemical treatment, the particle size effect, adsorbent concentration and pH effect. The results showed that the treatment employed in the green coconut shell powder with NaOH 0.1mol.L-/3h was the most efficient. This material was used for the metals adsorption study with the following characteristic: particle size ranged 60-99 mesh, adsorbent concentration (40g/L) and pH 5.0. The kinetic study indicated that the adsorption equilibrium multielementary were achieved in 5 minutes (pH 5.0) and followed a pseudo-second order model. The maximum capacities of adsorption observed for the multielementary system were: 7.89; 1.72; 3.24; 13.26 and 5.09mg/g to Pb+2; Ni+2; Cd+2; Zn+2 and Cu+2, respectively. In the second step of the work were carried out experiments to otimization of the operational parameters of the column. The results showed that for a flow rate of 2mL/min and height bed of 10cm there is an increased on the metals removal. The breakthrough curves investigated to a system multi indicated that the order for column capacity was the follow: Cu+2 > Pb+2 >Cd+2 > Zn+2 > Ni+2. The parameters optimization of the column obtained with the synthetic effluents were applied in a real sample contained (Ni+2, Zn+2 and Cu+2) which showed that the toxic ions removal increased at pH 5.0. The desorption of the metals ions retained on the column was efficient using the HNO3 1,0mol.L- as eluent. The tests of recycling of the column showed that the adsorbent can be used only a cycle.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:653
Date20 April 2007
CreatorsFrancisco Wagner de Sousa
ContributorsRonaldo Ferreira do Nascimento, Sandra TÃdde Santaella, Carlos Emanuel de Carvalho MagalhÃes
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia Civil, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds