Return to search

Modelagem da dispersão de trítio a partir de liberações acidentais postuladas de centrais nucleares

Submitted by Almir Azevedo (barbio1313@gmail.com) on 2013-12-09T13:21:48Z
No. of bitstreams: 1
dissertacao_mestrado_ien_2010_05.pdf: 3516447 bytes, checksum: d5e517dcd29d749cc561c5c7d57c3279 (MD5) / Made available in DSpace on 2013-12-09T13:21:48Z (GMT). No. of bitstreams: 1
dissertacao_mestrado_ien_2010_05.pdf: 3516447 bytes, checksum: d5e517dcd29d749cc561c5c7d57c3279 (MD5)
Previous issue date: 2010 / Este trabalho teve como objetivo avaliar o impacto de liberação acidental de
Trítio, postulada a partir de reator de potência, através de modelagem ambiental
no meio aquático. Para isso foram usados modelos computacionais hidrodinâmico
e de transporte para a simulação da dispersão de trítio causada por um acidente
em uma central nuclear do tipo CANDU 6, no sitio em construção de Angra 3
(PWR) no CNAAA. Este exercício foi realizado com auxílio de um sistema de
códigos acadêmico desenvolvido pelo Coppe/UFRJ, chamado SisBaHiA.
O CANDU é um reator que usa a água pesada (D2O) como moderador e
refrigerante do núcleo. Postulou-se então, um acidente do tipo LOCA (Loss of
coolant accident) no sistema de resfriamento emergencial do núcleo (sem fusão),
durante o qual foi quase instantaneamente perdido 66 m3 de refrigerante. Tal
inventário continha 35 PBq de trítio e foi lançada uma carga sob forma líquida de
9.7 TBq/s próximo a praia de Itaorna, Angra dos Reis – RJ.
Aplicando-se os modelos citados acima em dois cenários (usina parada e
em funcionamento), a diluição da atividade específica da pluma alcançou valores
superiores aos níveis de referência para água do mar (1.1 MBq/m³) previstos nas
especificações técnicas do licenciamento apenas durante os primeiros 14 dias
após o acidente. A diferença entre os dois cenários residiu basicamente na maior
diluição alcançada das maiores concentrações no cenário com recirculação de
água marinha (bombeamento e descarga) justamente nas primeiras duas
semanas, quando as concentrações entre a Praia de Itaorna e a Ilha Sandri
variaram 1×109 e 5×105 Bq/m³. Após 180 dias a pluma não poderia mais ser
detectada na Baía, pois sua atividade era inferior a mínima detectável (< 11
KBq/m³). / This study has the aim to assess the impact of accidental release of
tritium postulate from a nuclear power reactor through environmental modeling
of aquatic resources. In order to do that it was used computational models of
hydrodynamics and transport for the simulation of tritium dispersion caused by
an accident in a CANDU reactor located in the ongoing Angra 3 site. This
exercise was accomplished with the aid of a code system (SisBAHIA)
developed in the Rio de Janeiro Federal University (Coppe/UFRJ).
The CANDU reactor is one that uses heavy water (D2O) as moderator
and coolant of the core. It was postulated, then, the LOCA (Loss of coolant
accident) accident in the emergency cooling system of the nucleus (without
fusion), where was lost 66 m3 of soda almost instantaneously. This inventory
contained 35 PBq and was released a load of 9.7 TBq/s in liquid form near the
Itaorna beach, Angra dos Reis – RJ.
The models mentioned above were applied in two scenarios (plant
stopped or operating) and showed a tritium plume with specific activities larger
than the reference level for seawater (1.1 MBq/m³) during the first 14 days after
the accident. The main difference between the scenario without and with
seawater recirculation (pumping and discharge) is based on the enhancement
of dilution of the highest concentrations in the last one. This dilution
enhancement resulting in decreasing concentrations was observed only during
the first two weeks, when they ranged from 1x109 to 5x105 Bq/m³ close to the
Itaorna beach spreading just to Sandri Island. After 180 days, the plume could
not be detected anymore in the bay, because their activities would be lower
than the minimum detectable value (< 11 kBq/m³).

Identiferoai:union.ndltd.org:IBICT/oai:carpedien.ien.gov.br:ien/541
Date06 1900
CreatorsSOARES, Abner Duarte
ContributorsSIMÕES FILHO, Francisco Fernando Lamego, MÓL, Antônio Carlos de Abreu, MARQUES JUNIOR, Aguinaldo Nepomuceno, LAPA, Celso Marcelo Franklin
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional do IEN, instname:Instituto de Engenharia Nuclear, instacron:IEN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds