Análises multifísica via método de elementos finitos para o auxílio à manutenção preditiva em transformadores de potência. / Multiphysics analysis using a finite element method to aid predictive maintenance in power transformers.

Submitted by Luciclea Silva (luci@ufpa.br) on 2018-11-09T12:44:16Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Analisesmultisicametodo.pdf: 8640136 bytes, checksum: fb4885177a022217a3a13cc9edf858e7 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-11-09T12:44:35Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Analisesmultisicametodo.pdf: 8640136 bytes, checksum: fb4885177a022217a3a13cc9edf858e7 (MD5) / Made available in DSpace on 2018-11-09T12:44:35Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Analisesmultisicametodo.pdf: 8640136 bytes, checksum: fb4885177a022217a3a13cc9edf858e7 (MD5)
Previous issue date: 2018-09-21 / O Sistema Interligado Nacional (SIN) é um sistema de fundamental importância no panorama brasileiro. Sua função é conectar eletricamente os centros geradores e os centros consumidores, sendo eles empresariais, comercias ou residenciais. Os principais equipamentos responsáveis pela conexão e transmissão de energia elétrica dos centros geradores aos consumidores são os transformadores de potência. Esses equipamentos estão sujeitos a diversos tipos de falhas que podem afetar seus componentes chegando, em alguns casos, a comprometer a operação deste equipamento e, em consequência, o abastecimento de energia elétrica. Desta forma, neste trabalho é realizada uma análise multifisica nos transformadores de potência, acoplando simulações eletromagnéticas, térmicas e estruturais com o objetivo de fornecer ao operador informação sobre o momento ideal para a realização de manutenções preditivas, evitando paradas não planejadas. Para isso, foram utilizadas simulações computacionais por meio do Método de Elementos Finitos (MEF) e, a partir disso, foram analisadas as diversas situações as quais esses equipamentos podem ser submetidos, tanto na condição nominal, quanto em condições extremas de funcionamento, como corrente de inrush e corrente de curto-circuito. Nesta perspectiva, foram realizadas análises dos efeitos que a dilatação térmica e as forças axiais e radiais exercem, contribuindo para possíveis defeitos nesses equipamentos. Como objeto de estudo, as simulações foram realizadas em um transformador monofásico de 50 MVA, equipamento que encontra-se em funcionamento na região norte do país. Para melhor validação da metodologia utilizada neste trabalho, as simulações foram validadas com dados reais de medição e com resultados presentes em literaturas atuais. Desta forma, este trabalho apresenta uma metodologia que pode auxiliar o quadro técnico de uma indústria na decisão do momento adequado de parada em um transformador de potência para a realização de manutenções preditivas. / The National Interconnected System (NIS) is an organ of fundamental importance in the Brazilian panorama. Its function is to electrically connect generating centers and consumer centers, whether they are business, commercial or residential. The main equipment responsible for the connection and transmission of electric power from the generating centers to the consumers are the power transformers. This equipment is subject to several types of faults that can affect its components, in some cases compromising the operation of this equipment, and consequently the supply of electric energy. In this work, a multiphysical analysis is performed on power transformers, coupling thermal and structural electromagnetic simulations with the objective of providing the operator with information about the ideal moment for performing predictive maintenance, avoiding unplanned shutdowns. For this, computational simulations using the Finite Element Method (FEM) were used and from this, we analyzed the different situations that these equipments can be submitted, in the nominal condition, as well as extreme conditions of operation like current of inrush and current short-circuit. In this perspective, analyzes of the effects that the thermal expansion and the axial forces and radia exerted contributing to possible defects in these equipments were carried out. As a study object, the simulations were performed in a 50 MVA single-phase transformer, which is an equipment that is in operation in the northern region of the country. For a more validation of the methodology used in this work the simulations were validated with real measurement data and with results present in current literature. In this way, this work presents a methodology that can help the technical framework of an industry in the decision of the appropriate moment of stop in a power transformer for the accomplishment of predictive maintenance.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10383
Date21 September 2018
CreatorsSOUSA, Antonio Roniel Marques de
ContributorsNUNES, Marcus Vinicius Alves
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Source1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0158 seconds