Return to search

Implementação do religamento monopolar adaptativo rápido baseado na assinatura harmônica de tensão no simulador digital em tempo real (RTDS) / Implementation of fast adaptive single-phase reclosing based on measurement of harmonic content in the real-time digital simulator (RTDS)

Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T00:34:34Z (GMT). No. of bitstreams: 1
Dias_OzenirFarahdaRocha_M.pdf: 5023742 bytes, checksum: b0fe9b9418551d927583a884fbec6e92 (MD5)
Previous issue date: 2015 / Resumo: Este trabalho apresenta a implementação de um esquema de religamento monopolar adaptativo rápido baseado na medição do conteúdo harmônico da tensão da fase aberta nas extremidades da linha de transmissão. O objetivo principal deste esquema é controlar e reduzir o tempo compreendido entre a abertura e o religamento da fase em falta, como também bloquear a manobra em caso de faltas permanentes. O esquema proposto foi implementado em um relé de distância e um medidor de conteúdo harmônico. O método está baseado na identificação do instante de extinção da corrente de arco secundário para casos de faltas transitórias. Já para faltas permanentes é implementado o bloqueio da manobra automática e a abertura tripolar do disjuntor da linha protegida. A medição do conteúdo harmônico foi feita primeiramente utilizando um medidor de qualidade de energia comercial, que realiza a medição do conteúdo harmônico de acordo com a norma IEC 61000-4-3. Em seguida, foi utilizado outro método de medição do conteúdo harmônico, chamado de filtro de medição do conteúdo harmônico rápido, elaborado dentro do Simulador Digital em Tempo Real (RTDS). O sistema de transmissão utilizado foi modelado no RTDS e seus dados são dados reais do sistema interligado nacional (SIN). As faltas monofásicas transitórias foram simuladas utilizando o modelo de arco do próprio RTDS. Já para falta permanente utilizou-se uma resistência de 1 'ômega'. O esquema foi avaliado através de testes variando o ponto de aplicação do defeito e o valor da corrente de arco secundário / Abstract: This work presents the implementation of a scheme of fast adaptive single-phase reclosing based on measuring the voltage harmonic content at the opened faulty phase terminals. The main objective of this scheme is to control and to reduce the time between opening and reclosing of the phase in fault, and also to block the maneuver in case of permanent faults. The proposed scheme is implemented in a distance relay and a harmonic content meter. The method is based in the identification of the secondary arc current extinction moment for transient faults cases. For permanent faults an automatic blocking followed by circuit-breaker three-phase opening is implemented. The measurement of harmonic content was made initially using a commercial power quality meter, which performs the harmonic content measurement according to IEC 61000-4-3 standard. Another harmonic content measurement method was tested, the fast harmonic content filter measurement, elaborated within the real-time digital simulator (RTDS). The transmission system used was modeled on RTDS and the data corresponds to an actual Brazilian 500 kV system. To represent the transient single-phase fault it was used RTDS arc model. The permanent fault was modeled with an 1'ômega' resistance. The scheme was evaluated by varying the fault application point and the secondary arc current value / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259596
Date27 August 2018
CreatorsDias, Ozenir Farah da Rocha, 1988-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tavares, Maria Cristina Dias, 1962-, Camara, Alessandra de Sa e Benevides, Gertrudes, João Bosco
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format150 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess