Return to search

Conteúdo harmônico e estimativa da variação de comprimento de arcos elétricos gerados artificialmente em linhas de transmissão = Harmonic content and estimation of length variation of artificially generated electrical arc in transmission lines / Harmonic content and estimation of length variation of artificially generated electrical arc in transmission lines

Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T16:31:47Z (GMT). No. of bitstreams: 1
Talaisys_JonasLemos_M.pdf: 12385917 bytes, checksum: 5619a3284121ab56d2a0a337ef2456b4 (MD5)
Previous issue date: 2012 / Resumo: Este trabalho apresenta resultados do estudo do conteúdo harmônico e da variação do comprimento de arcos elétricos longos, com comprimento inicial superior a 4 m. Os resultados decorreram da análise de uma grande quantidade de dados obtidos de 647 ensaios realizados em ambiente não confinado em um trecho experimental de linha de transmissão aérea de 500 kV. Diversos níveis de corrente de arco foram abrangidos, desde 15 Aef até 10.000 Aef. O conteúdo harmônico da tensão e da corrente dos arcos foi analisado através da Trans-formada de Fourier Discreta em Tempo Reduzido. Mediante um tratamento estatístico, este conteúdo harmônico possibilitou a consolidação da assinatura harmônica dos arcos estudados. Uma contribuição importante da pesquisa consiste na verificação de que o conteúdo harmônico do arco pode ser utilizado para identificar o momento a partir do qual o arco elétrico se encontra com suas características elétricas estabilizadas. A partir deste instante os parâmetros elétricos do arco podem ser utilizados para obtenção de um modelo matemático. Utilizando-se do conteúdo harmônico e de registros visuais, a variação de comprimento foi obtida para 69 arcos. Esta análise inicial permite que se tenha uma noção da velocidade de alongamento destes arcos em relação ao seu nível de corrente. Permitiu também a obtenção de um gradiente de tensão mais preciso dos arcos, considerando-se tanto o alongamento quanto a estabilidade destes. Por fim, este trabalho tem por objetivo apresentar resultados que forneçam características e informações relevantes à obtenção de um modelo matemático de arco elétrico secundário adequado para o estudo da Manobra de Abertura e Religamento Monopolar. O conteúdo harmônico é identificado como uma ferramenta eficaz para caracterização da estabilidade destes arcos e o alongamento é um dos principais fatores relacionados com a extinção e duração do arco secundário / Abstract: This document presents results related to harmonic content and length variation of long electrical arcs in air, with initial length of 4 m. The results are based in the analysis of a data-base containing 647 experiments in non-confined environment of an experimental aerial 500 kV transmission line. The current range analyzed lies between 15 Arms and 10,000 Arms. The harmonic contents of voltage and current of electrical arcs were analyzed by the Short Time Discrete Fourier Transform. Using a statistic treatment this harmonic content allowed to consolidate the harmonic signature of the arcs in study. Furthermore, in the present work it was proposed that the harmonic content of an electrical arc defines the moment when the electric arc has its electrical characteristics stabilized. This instant is crucial to obtain the correct arc electrical parameters that will used to represent the arc. Using the harmonic content and visual data, the variation in length was obtained for 69 arcs. This initial analysis lead to arc elongation velocity regarding the current level and permit-ted to obtaining a more precise arc voltage gradient, considering both elongation as its stability. Finally, this work aims to supply relevant characteristics and information to obtaining a secondary arc model useful to the Single-Phase Autoreclosing Maneuver study. The harmonic content is an efficient way to characterize these arcs and the arc elongation is one of the main factors related to the duration and self-extinction of the secondary arc / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259600
Date21 August 2018
CreatorsTalaisys, Jonas Lemos
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tavares, Maria Cristina Dias, 1962-, Camara, Alessandra de Sa e Benevides, Valero, Patricia Mestas
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format120 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess