Return to search

Bearing Strength of Cold Formed Steel Bolted Connections in Trusses

The existing design provision in North American Specification for Cold- Formed Steel Structural Member (AISI S100) for the bearing strength of bolted connections were developed from tests on bolted connected sheets which were restrained by bolt nut and head with or without washers. However, in the cold-formed assemblies, particularly in trusses, the single bolt goes through both sides of the connected sections, making the connected sheets on each side unrestrained. the warping of the unrestrained sheet may reduce the bearing strength of the bolted connection. This research investigates the behavior and strength of bearing failure in bolted connections in cold-formed steel trusses. Tensile tests were conducted on trusses connections with various material thicknesses. It was found that the AISI S100 works well for thick connections but provides unconservative predictions for thin materials. Based on the experimental results, a modified bearing strength method is proposed for calculating the bearing strength of bolted truss connections. the proposed method can be used for any cold-formed steel connections with unrestrained sheet.

Identiferoai:union.ndltd.org:unt.edu/info:ark/67531/metadc115135
Date05 1900
CreatorsPanyanouvong, Mark
ContributorsYu, Cheng, DeSimone, Diane, Zhange, Haifeng, Anaya, Leticia
PublisherUniversity of North Texas
Source SetsUniversity of North Texas
LanguageEnglish
Detected LanguageEnglish
TypeThesis or Dissertation
FormatText
RightsPublic, Panyanouvong, Mark, Copyright, Copyright is held by the author, unless otherwise noted. All rights Reserved.

Page generated in 0.0094 seconds