Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-02-27T16:50:13Z
No. of bitstreams: 1
2017_AmauriGutierrezMartinsBritto.pdf: 6835076 bytes, checksum: 703a759616cacaf543f15db19619735e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-05-23T14:31:26Z (GMT) No. of bitstreams: 1
2017_AmauriGutierrezMartinsBritto.pdf: 6835076 bytes, checksum: 703a759616cacaf543f15db19619735e (MD5) / Made available in DSpace on 2018-05-23T14:31:26Z (GMT). No. of bitstreams: 1
2017_AmauriGutierrezMartinsBritto.pdf: 6835076 bytes, checksum: 703a759616cacaf543f15db19619735e (MD5)
Previous issue date: 2018-03-23 / Este trabalho descreve o problema de interferências eletromagnéticas entre linhas de transmissão de energia elétrica em alta tensão e tubulações metálicas, decorrentes dos fenômenos de acoplamento indutivo, condutivo e capacitivo, e os principais riscos a que dão causa, em especial os relacionados à segurança de pessoas e das instalações envolvidas. É desenvolvido um conjunto de ferramentas computacionais destinado à predição dos níveis de tensões e correntes induzidas em um circuito vítima, nos casos de aproximações entre LTs aéreas e tubulações subterrâneas, com as seguintes funcionalidades principais: 1) cálculo dos parâmetros do solo estratificado em camadas horizontais; 2) cálculo das forças eletromotrizes induzidas no metal da tubulação por acoplamento magnético; 3) cálculo das impedâncias no domínio de sequências de LTs sujeitas a interferências; e 4) cálculo das tensões de estresse produzidas pela elevação de potencial do solo (acoplamento condutivo) em um evento de falta. Os programas são validados por meio de estudos de casos e comparações com os resultados de softwares difundidos na indústria ou, nos casos possíveis, com medições diretas de potenciais CA. São estudadas as respostas em tensão de toque, passo e estresse nas tubulações interferidas, bem como são avaliados os efeitos da presença da tubulação metálica sobre os parâmetros elétricos da LT e os impactos provocados nos níveis de curto-circuito e desempenho de dispositivos de localização de faltas. É ressaltada a necessidade de se utilizar métodos computacionais precisos e realistas, zelando pela qualidade das informações coletadas em campo, em especial a resistividade elétrica do solo e o levantamento cadastral de interferências com as instalações em estudo, sob pena de se incorrer em graves erros de projeto, tais como: falhas de dimensionamento de sistemas de aterramento, mitigação, equipamentos e funções de proteção e dispositivos de localização de faltas, ocasionando exposição a riscos de eletrocussão de pessoas e danos ao patrimônio. / This work describes the problem of electromagnetic interference between high voltage power lines and metallic pipelines, caused by inductive, conductive and capacitive coupling mechanisms, and the main risks to which people and facilities are exposed. A set of computational tools is developed to predict induced voltage and current levels on a victim circuit, due to interferences between overhead power lines and underground pipelines. The implementation takes into account the 1) calculation of soil stratification parameters for a horizontally layered model; 2) calculation of induced electromotive forces on the pipeline metal, caused by magnetic coupling; 3) calculation of transmission line sequence parameters under interference conditions; and 4) calculation of stress voltages produced by the ground potential rise (conductive coupling) under fault circumstances. The programs are validated through case studies and comparisons with results taken from software used in industry or, when possible, with direct measurements of AC potentials. Touch, step and stress voltages are studied, as well as the effects of the pipeline proximity on the transmission line parameters and the resulting impacts on short-circuit currents and performance of fault locating devices. This work highlights the importance of employing accurate and realistic computational methods, along with gathering consistent field data, especially soil resistivity measurements and records of geographic locations of nearby interfering structures. Not doing so may cause serious design errors, such as inadequate sizing of power grounding and mitigation systems, protection function and equipment, as well as fault location devices, exposing people and installations to risks.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/31965 |
Date | 10 November 2017 |
Creators | Britto, Amauri Gutierrez Martins |
Contributors | Soares, Antonio José Martins, Lopes, Felipe Vigolvino |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess |
Page generated in 0.0118 seconds