The aim of this thesis is to investigate PMSM models with internal faults. Two fault models are introduced. One of them is suitable for simulation of stator winding inter-turn short fault in case of one pole-pair motor and other one for simulation of inter-turn fault in case of multiple pole-pair motor. There are described some methods for model based fault detection of internal faults and sensor faults.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:220904 |
Date | January 2014 |
Creators | Kozel, Martin |
Contributors | Veselý, Libor, Václavek, Pavel |
Publisher | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0018 seconds