Orientador: Niederauer Mastelari / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-21T01:52:02Z (GMT). No. of bitstreams: 1
Danes_LeandroHenschel_M.pdf: 2871625 bytes, checksum: b9af585f9ca0d24b08f2435b57a913bc (MD5)
Previous issue date: 2012 / Resumo: Uma mistura de gás e liquido escoando em um tubo em diferentes faixas de vazões se comporta como diferentes padrões de escoamento, em que interações cinemáticas e dinâmicas especificas de cada padrão, ocorrem entre gás e liquido. A estimação de dados sobre a velocidade media de deslocamento e a vazão de ambas as fases depende da aplicação de estratégias estatísticas de e de modelos de escoamento para calcular estas informações. Neste trabalho, um sensor de impedância que, se devidamente calibrado, possui sinal proporcional ao nível de liquido na seção transversal do duto, foi utilizado para a obtenção destes dados sendo desenvolvidas técnicas e estratégias para alcançar este objetivo. O estudo foi desenvolvido no regime de escoamento horizontal água-ar nos regimes de bolhas alongadas, estratificado intermitente. Foram utilizadas técnicas para a obtenção da velocidade media de deslocamento do escoamento bifásico a partir de um arranjo de dois sensores de impedância em serie. Foi utilizada a técnica da correlação cruzada e foram elaboradas e apresentadas como opção, uma técnica baseada no calculo numérico e outra na covariância entre os sinais como alternativa. As técnicas foram testadas e comparadas. Foram utilizados modelos de escoamento e levantadas hipóteses para a estimativa das vazões de gás e liquido. Foram realizadas estimativas para o padrão de bolhas alongadas, estratificado e intermitente. Para o regime intermitente, considerado foco do estudo, foram obtidas respectivamente para gás e liquido, margens de erro de 24.4% e 28% considerando um perfil de escoamento constante e margens de 12.5% e 20.5% para um perfil laminar / Abstract: A gas-liquid moisture flowing in a tube at different flow rates , behaves as different flow patterns, which cinematic and dynamic interactions occurs between the gas and liquid phases. The estimation of average displacement rate data and flow data for both phases depends of the application of statistical strategies and floe models for calculating the information. In this work, a impedance sensor which, is correctly calibrated, has a proportional out to the liquid level of the tube cross section, was used for obtaining these data with techniques and strategies developed to achieve this goal. The study was developed for horizontal air-water flow at the bubbles, stratified and slug patterns. It was used techniques for obtaining the average displacement speed of the flow between the two sensors. The cross-correlation technique was used and a numeric calculus based technique and a covariance based technique were elaborated and presented as an option. The techniques were tested and compared. Flow-models were used and hypothesis were take in order to make estimations of gas and liquid flow magnitude. Estimatives were done for the elongated bubbles , stratified and slug patterns. For the slug pattern ,focus of the work, it was obtained respectively for the gas and the liquid phase, error margins of 24,4% and 28% considering a constant flow profile and 12.5% and 20.5% margins considering a laminar flow profile / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/263023 |
Date | 07 April 2012 |
Creators | Danés, Leandro Henschel, 1986- |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Mastelari, Niederauer, 1961-, Moura, Luiz Felipe Mendes de, Silva, Marco José da |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 189 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.003 seconds