Return to search

Influencia da ultrafiltração na remoção de mediadores inflamatorios durante circulação extracorporea e alterações da função organica monitorada pelo "Sequencial Organ Failure Assessment Score - SOFA" em pacientes submetidos a revascularização do miocar / Inflammatory mediators and sequencial organ failure assessment score - SOFA outcomes after conventional ultrafiltration during circulatory bypass in patients underwent coronary artery bypass graft

Orientador: Desanka Dragosavac, Luis Alberto Magna / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-14T08:33:07Z (GMT). No. of bitstreams: 1
Antunes_Nilson.pdf: 1392711 bytes, checksum: 89e9cd241a2037104655c013c2724bfc (MD5)
Previous issue date: 2009 / Resumo: Objetivo: Investigar a eficácia da ultrafiltração na remoção de mediadores inflamatórios liberados pela circulação extracorpórea e correlacionar ultrafiltração com alterações da função orgânica de acordo com o "Seqüential Organ Failure Assessment Score". Métodos: Quarenta pacientes foram incluídos e randomizados em dois grupos: "sem ultrafiltração" (n=20; Grupo I) e "ultrafiltração" (n=20; Grupo II). Complementos 3 e 4 ativados, interleucina 1beta, 6, 8 e fator de necrose tumoral alfa foram dosados antes da indução anestésica (T1), 5 minutos antes da circulação extracorpórea (T2), no líquido ultrafiltrado (T3), 30 minutos (T4), 6 (T5), 12 (T6), 24 (T7), 36 (T8) e 48 (T9) horas após término da circulação extracorpórea. "Sequential Organ Failure Assessment Score" foi avaliado nos tempos 1, 6 e 9. Significância estatística foi estabelecida com p = 0,05. Resultados: No líquido ultrafiltrado, apenas níveis de fator de necrose tumoral alfa foram detectados. Níveis de complemento 3 ativado, nos tempos 5 e 7, e complemento 4 ativado, nos tempos 5 e 6, foram significativamente elevados no grupo sem ultrafiltração, e níveis de interleucina 6 foram elevados no grupo ultrafiltrado, nos tempos 7 e 8. Interleucina 1beta, 8, fator de necrose tumoral alfa, e "Sequential Organ Failure Assessment Score" não tiveram diferenças significantes entre os grupos. Conclusões: Ultrafiltração retira significativamente fator de necrose tumoral alfa, mas isto não influencia nos níveis séricos desta citocina. Ultrafiltração com o tipo de filtro usado neste estudo não filtra outros mediadores inflamatórios estudados e não diminui a disfunção orgânica no pós-operatório. Deverá ser usada apenas para controle volêmico nos pacientes submetidos à circulação extracorpórea. / Abstract: Objective: To investigate the effectiveness of ultrafiltration in removing inflammatory mediators released by cardiopulmonary bypass and to correlate ultrafiltration with alterations in organic function according to the Sequential Organ Failure Assessment Score. Methods: Forty patients were included and randomized into two groups: "no ultrafiltration" (n=20; Group I) and "ultrafiltration" (n=20; Group II). Activated complement 3 and 4, interleukins 1beta, 6, 8 and tumor necrosis factor alfa were measured prior to anesthesia induction (Time 1), 5 minutes before cardiopulmonary bypass (Time 2), in the ultrafiltrated fluid (Time 3), 30 minutes (Time 4), and 6 (Time 5), 12 (Time 6), 24 (Time 7), 36 (Time 8) and 48 (Time 9) hours following cardiopulmonary bypass. Sequential Organ Failure Assessment Score was evaluated at Time 1, 6 and 9. Statistical significance was established at p = 0.05. Results: In the ultrafiltrated fluid, only tumor necrosis factor alfa levels were detected. Levels of activated complement 3 at Times 5 and 7 and activated complement 4 at Times 5 and 6 were significantly higher in the unfiltered Group, and levels of interleukin 6 were higher in the filtered Group at Times 7 and 8. Interleukins 1beta, 8, tumor necrosis factor alfa, and the Sequential Organ Failure Assessment score were not significantly different between the groups. Conclusions: Ultrafiltration significantly filtered tumor necrosis factor alfa but did not influences serum levels of this cytokine. Ultrafiltration with the type of filter used in this study had no effect in organic dysfunction and should be used only for volemic control in patients undergoing cardiopulmonary bypass. / Universidade Estadual de Campi / Pesquisa Experimental / Doutor em Cirurgia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/313474
Date14 August 2018
CreatorsAntunes, Nilson
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Magna, Luis Alberto, 1954-, Dragosavac, Desanka, 1951-, Toro, Ivan Felizardo Contrera, Araújo, Sebastião, Martins, Antonio Sergio, Gomes, Walter Jose
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format86 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds