Uncertainty analysis of integrated powerhead demonstrator mass flowrate testing and modeling

A methodology has been developed to quantify the simulation uncertainty of a computational model calibrated against test data. All test data used in the study undergoes an experimental uncertainty analysis. The modeling software ROCETS is used and its structure is explained. The way the model was calibrated is presented. Next, a general simulation uncertainty analysis methodology is shown that is valid for calibrated models. Finally the ROCETS calibrated model and its simulation uncertainty are calculated using the general methodology and compared to a second set of comparison test data. The simulation uncertainty analysis methodology developed and implemented can be used for any modeling with a calibrated model. The methodology works well for a process of incremental testing and recalibration of the model whenever new test data is available.

Identiferoai:union.ndltd.org:MSSTATE/oai:scholarsjunction.msstate.edu:td-5811
Date06 August 2005
CreatorsMolder, King Jeffries
PublisherScholars Junction
Source SetsMississippi State University
Detected LanguageEnglish