Design of a Gravity Compensation Actuator for Arm Assistance

This thesis presents the design, simulation, and evaluation of a passive, wearable, and human-scale actuator that includes pulleys and uses polymers for energy storage. Repetitive tasks such as packing boxes on an assembly line may require high strength movements of the shoulder, arm, and hand and may result in musculoskeletal disorders. With the objective to offset the weight of the arm and thereby lower the forces on the muscles in the shoulder and arm, this actuator is able to provide gravity compensation for the upper extremities of workers, if used in conjunction with an arm exoskeleton. The actuator is passive, meaning that it does not use motors or sensors, but instead creates a force on a cable that is a function of the displacement of the cable.

This thesis details the design of the actuator and the selection of an appropriate polymer for use with the actuator. To determine the best polymer for this application, tests were conducted on nine polymers to ind their average Young's modulus and their hysteresis. A 90A abrasion-resistant polyurethane rubber belt was used in the final design due to its high modulus and low hysteresis. The final actuator design was tested in an Instron machine to validate its performance. During testing, the actuator provided 720N in extension and 530N in retraction, which are roughly 112% and 83% of the torque required to lift a human arm, respectively. / Master of Science / The development of industry increases productivity, and brings convenience to people’s life, but in the meantime it also increases work-related illnesses. Based on such condition, mechanical devices such as exoskeletons can be applied to support arms of wearer to perform tasks for longer durations and with less effort. In this thesis, we present a wearable actuator that contains pulleys and polymer belts. With rather light weight and small size, the actuator is located on the waist of wearer, and connected to the arm exoskeleton by cable. As the arm moves, the polymer belts within the actuator will be stretched and counteract the effects of movements. All in all, the design of the actuator must be portable, light-weight and with simple design that can be sufficient to meet actual requirements.

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/82201
Date19 February 2018
CreatorsTang, Chen
ContributorsMechanical Engineering, Asbeck, Alan T., Ben-Tzvi, Pinhas, Parker, Robert G.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
Detected LanguageEnglish
TypeThesis
FormatETD, application/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/

Page generated in 0.0025 seconds