Orientadores: Antonio Celso Fonseca de Arruda, Aron Jose Pazin de Andrade / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-09T06:51:30Z (GMT). No. of bitstreams: 1
Bock_EduardoGuyPerpetuo_M.pdf: 3873649 bytes, checksum: 91eb2ac5543b164e576ca7a5e61d6a45 (MD5)
Previous issue date: 2007 / Resumo: Uma bomba centrífuga implantável foi projetada e construída para assistência ventricular de longa duração no tratamento de pacientes portadores de doenças cardiovasculares. A metodologia utilizada foi a de testes de desempenho ¿in vitro¿ compostos de testes de atrito para seleção de materiais para os mancais de apoio, testes de desempenho hidrodinâmico da bomba e testes com sangue humano para a verificação da hemólise causada no bombeamento. Os primeiros testes foram realizados com uma bomba centrífuga não implantável, normalmente utilizada em cirurgias cardíacas, para a determinação do posicionamento do orifício de entrada da bomba. Foram realizadas simulações numéricas por computador para dimensionamento da bomba. Testes de atrito foram feitos para a seleção de materiais do sistema de mancais de apoio proposto para alcançar a durabilidade necessária. Testes de desempenho hidrodinâmico foram utilizados para determinar o melhor desenho para o rotor da bomba. Seu desempenho foi comparado com uma bomba não implantável e com uma bomba implantável similar americana e apresentou melhores resultados que ambas. Testes com sangue foram feitos para quantificar os danos causados aos componentes do sangue pela bomba. O seu índice normalizado de hemólise foi de 0,0054 mg/100L, considerado excelente por se encontrar próximo do limite mínimo encontrado na literatura: entre 0,004 g/ 100L e 0,02 g/ 100L. Como trabalhos futuros, serão feito testes com animais para que a bomba centrífuga implantável possa ser utilizada em pacientes / Abstract: An implantable centrifugal blood pump was developed for long-term ventricular assistance in cardiac patients. In vitro tests were performed, as wear evaluation, performance tests and hemolysis tests in human blood. Preliminary tests were performed with a non-implantable pump in order to properly locate the inlet port. Numerical computational simulations were performed in order to predict its best geometry. Wear evaluations helped to select the best materials for double pivot bearing system proposed to achieve longer durability. Performance tests pointed the best impeller geometry. The implantable centrifugal blood pump was compared with other two blood pumps. One is a centrifugal blood pump for cardiopulmonary bypass and the other is a similar implantable device. The proposed implantable centrifugal blood pump showed the best performance. But, its results showed a strong descendant curve in high flow. Other prototype was manufactured with a different inlet port angle to overcome this problem. The normalized index of hemolysis (NIH) tests was performed with human blood pumped in an In Vitro closed circuit (mock loop) in normalized conditions, as flow of 5 L/min and total pressure ahead of 100 mm Hg. After six hours, NIH measured 0.0054 mg/100L that can be considered excellent since it is close to the minimum found in literature (between 0.004 g/ 100L e 0.02 g/ 100L). As future work, in vivo test will be performed with the implantable centrifugal blood pump looking forward to implant it in patients / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/263269 |
Date | 02 May 2007 |
Creators | Bock, Eduardo Guy Perpétuo |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Andrade, Aron José Pazin de, Arruda, Antonio Celso Fonseca de, 1948-, Zavaglia, Cecília Amélia de Carvalho, Horikawa, Oswaldo |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 110p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0031 seconds