OBJETIVO: Investigar a correlação entre as espessuras da mácula e da camada de fibras nervosas da retina (CFNR), medidas pelas tomografias de coerência óptica de domínio Fourier (FD - OCT) e de domínio do tempo (TD - OCT) e a perda de sensibilidade no campo visual (CV) em pacientes com atrofia em banda do nervo óptico. Comparar a habilidade diagnóstica dos dois instrumentos. MÉTODOS: 36 olhos de 36 pacientes com perda de CV permanente por compressão do quiasma óptico e 36 controles normais foram submetidos ao exame de CV pela perimetria automatizada padrão (Humphrey Field Analyzer TM; Carl Zeiss Meditec, Dublin, CA), ao FD - OCT (3 D OCT-1000TM Topcon Corp., Tokyo, Japan) e ao TD - OCT (StratusTM ;Carl Zeiss Meditec Inc, Dublin, California, USA). Foram comparados os protocolos análogos de ambos os equipamentos para avaliação da espessura macular.Foi realizado a divisão macular em quatro quadrantes e em metades, sendo calculado a média da espessura macular global, a média da espessura dos quadrantes e a média da espessura das metades maculares. A média global e setorial da medida da espessura da CFNR peripapilar também foi analisada. A perda de sensibilidade no CV foi inicialmente avaliada pelo defeito temporal médio. O CV foi ainda dividido em 6 setores de acordo com a distribuição da CFNR e em 16 pontos centrais para a realização da correlação estrutura-função entre os parâmetros medidos pelo FD - OCT e a perda de sensibilidade no CV em decibéis e 1/Lambert. Foi calculado o coeficiente de correlação de Sperman e a análise de regressão linear. As áreas sobre a curva ROC e valores fixos de sensibilidade e especificidade foram calculados para cada parâmetro estudado. RESULTADOS: As medidas da espessura macular e da CFNR pelo FD - OCT e TD - OCT foram capazes de discriminar olhos com atrofia em banda do nervo óptico dos controles normais. A espessura global e setorial dos parâmetros maculares e da CFNR mostraram diferenças significativas (p<0,001) entre os doentes e os controles e os dois aparelhos tiveram desempenho semelhante na discriminação entre pacientes e controles. Em ambos existiram correlações significativas entre a perda de sensibilidade do CV e as medidas da espessura macular e da CFNR. As medidas de espessura nos quadrantes e nas metades nasais da macula, avaliadas pelo FD - OCT tiveram os melhores desempenhos nas correlações com os defeitos de CV, sendo o parâmetro com a melhor correlação, a medida do quadrante infero-nasal da mácula e a perda de sensibilidade do CV central do quadrante temporal superior central (r = 0.78, R2 = 61%, p<0,001). CONCLUSÕES: A espessura macular e a espessura da CFNR medidas pelo FD - OCT e pelo TD - OCT se correlacionaram topograficamente com a perda de sensibilidade no CV de pacientes com hemianopsia temporal por compressäo quiasmática. A correlação entre os quadrantes maculares e a perda de sensibilidade no CV, foram melhores do que aquelas entre o CV e as medidas da CFNR, principalmente nas medidas realizadas pelo FD - OCT. Este estudo demonstrou a importância clínica das medidas maculares na correlação estrutura-função e na quantificaçäo do dano neural em pacientes com compressão quiasmática, podendo ser útil na monitorização destes pacientes / PURPOSE: To investigate the relationship between fourier-domain optical coherence tomography (FD - OCT) measured macular and retinal nerve fiber layer thickness (RNFL) and visual field sensitivity loss on standard automated perimetry in eyes with permanent temporal hemianopia from chiasmal compression and compare the ability of FD - OCT and time-domain optical coherence tomography (TD - OCT) to detect axonal loss in eyes with band atrophy of the optic nerve. METHODS: One eye of each of 36 patients with permanent temporal visual field defects and 36 age- and sex-matched healthy subjects. Subjects underwent standard automated perimetry and macular and RNFL thickness measurements with FD - OCT (3 D OCT-1000® Topcon Corp., Tokyo, Japan) and TD - OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA). Macular thickness measurements as a global average, divided in four quadrants and in two halves as well as average and sectoral RNFL thickness around the optic disc were calculated. Visual field sensitivity loss was evaluated by the temporal mean defect; as deviations from normal in six sectors of the visual field and in 16 central visual field test points. Relationship between visual field sensitivity loss in decibel and 1/Lambert units and optical coherence tomography measurements were evaluated using Spearman correlation coefficients and by linear regression analysis. Receiver operating characteristic curves and sensitivities at fixed specificities were calculated for each parameter. RESULTS: Global and sectoral macular and RNFL thickness parameters showed a significant difference in eyes with band atrophy compared with controls. The strongest correlations were seen between visual field sensitivity loss and quadrantic or hemianopic nasal macular thickness measurements than with sectoral retinal nerve fiber layer thickness measurements. The highest correlation was observed between the inferonasal quadrant macular thickness and the visual field sensitivity loss in the superior temporal central visual field quadrant (r = 0.78, R2 = 61%, p <0.001). CONCLUSION: Both RNFL thickness and macular thickness FD - OCT and TD - OCT measurements were related topographically with visual field sensitivity loss in patients with temporal hemianopia from chiasmal compression and there is a stronger relationship in quadrantic macular compared to RNFL thickness measurements with FD - OCT. Macular thickness measurements could potentially be used to quantify neuronal loss in patients with chiasmal compression and could prove clinically useful for detection of damage and for monitoring these patients
Identifer | oai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-21072011-134114 |
Date | 18 April 2011 |
Creators | Luciana Virginia Ferreira Costa Cunha |
Contributors | Mario Luiz Ribeiro Monteiro, Francisco Max Damico, Maria Kiyoko Oyamada, Lisandro Massanori Sakata, Joyce Hisae Yamamoto |
Publisher | Universidade de São Paulo, Oftalmologia, USP, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0021 seconds