Desarrollo de un sistema de degradación de aguas residuales de la industria textil de pantalones de vaquero utilizando la técnica de Foto-Fenton

El trabajo propuesto consiste en el tratamiento de las aguas residuales que se generan en la industria textil, sobre todo en las pequeñas y medianas empresas de dicho rubro, ya que muchas de ellas no cuentan con un sistema de tratamiento de aguas residuales y las que sí, no realizan un sistema adecuado para dicha labor. Actualmente existen máquinas capaces de realizar un tratamiento de aguas residuales adecuado, pero no son del todo automatizadas y el precio de éstas son considerablemente altos. En base a esta problemática, se buscó una solución con que no cuente con un número excesivo de etapas, que no genere residuos durante el tratamiento, que sea un proceso automatizado y con un tiempo óptimo de proceso. Por estos motivos, se optó por el método del Foto-Fenton como la solución idónea para realizar el tratamiento de aguas residuales, el cual necesita que el efluente tenga un pH igual a 3 para lo cual que realizará un lazo de control. Adicionalmente, requiere dos soluciones químicas y una luz UV. Los resultados obtenidos de este proyecto fueron satisfactorios ya que se llegó a cumplir los estándares ambientales de NTU (Unidad de Turbidez Nefelométrica), los cuales indican que para poder botar el agua al alcantarillado, debe tener un máximo valor de 100NTU. Cabe resaltar que este proyecto realizará todo el proceso de forma automatizada y sólo se va a centrar en las aguas residuales provenientes del proceso de los pantalones de vaqueros de color azul. / The proposed work consists of the treatment of wastewater generated in the textile industry, especially in small and medium-sized companies in this area, since many of them do not have a wastewater treatment system and those that do , not making an adequate system for such work. Currently there are machines capable of carrying out an adequate wastewater treatment, but they are not fully automated and the price of them is considerably high. Based on this problem, a solution was sought that does not have an excessive number of stages, that does not generate waste during the treatment, that is an automated process and with an optimal process time. For these reasons, the Foto-Fenton method was chosen as the ideal solution for treating wastewater, which requires the effluent to have a pH equal to 3 for a control loop to be performed. Also, two chemical solutions and one UV light are required. The results obtained from this project were satisfactory since the environmental standards of NTU (Nephelometric Turbidity Unit) were met, which indicate that in order to discharge the water to the sewer, it must have a maximum value of 100NTU. It should be noted that this project will execute the entire process in an automated way and will only focus on the wastewater from the blue jeans process. / Tesis

Identiferoai:union.ndltd.org:PERUUPC/oai:repositorioacademico.upc.edu.pe:10757/657106
Date24 July 2021
CreatorsChico Pachas, Hugo Gian Pool, López Vera, Jorge André
ContributorsKlusmann Vieira, Hermann Mirko
PublisherUniversidad Peruana de Ciencias Aplicadas (UPC), PE
Source SetsUniversidad Peruana de Ciencias Aplicadas (UPC)
LanguageSpanish
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/bachelorThesis
Formatapplication/pdf, application/epub, application/msword
SourceRepositorio Académico - UPC, Universidad Peruana de Ciencias Aplicadas (UPC)
Rightsinfo:eu-repo/semantics/openAccess, Attribution-NonCommercial-ShareAlike 4.0 International, http://creativecommons.org/licenses/by-nc-sa/4.0/

Page generated in 0.0022 seconds