Return to search

Alteração do ponto de alimentação da rede objetivando a redução de perdas : estudo de caso / Changing the network feed point with the intent of reducing losses : case study

Orientador: Paulo Vatavuk / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T16:05:38Z (GMT). No. of bitstreams: 1
Costa_EdsonSeneda_M.pdf: 9039767 bytes, checksum: e9d0b4f243d44d427133eff873f18844 (MD5)
Previous issue date: 2014 / Resumo: O problema de perdas de água em redes de abastecimento é um dos principais desafios dos gestores dos sistemas. Neste trabalho pretende-se avaliar um caso prático no qual a alteração do ponto de alimentação da rede de água possibilitou redução de perda de água devido à diminuição das pressões na área estudada. A região central do município de Cotia abastecido pelo setor Cotia-Jardim Atalaia, tinha o ponto de alimentação da rede situado em um local distante de seu ponto crítico alto. Devido ao crescimento populacional, este reservatório ficou com a demanda de água maior que a oferta, e, houve a necessidade de realizar a diminuição de sua área de atuação. Para resolver a questão, a área de estudo foi retirada do setor Cotia-Atalaia e passou a ser abastecida pelo setor Cotia-Centro que suportou o acréscimo de vazão. Com essa mudança, o novo ponto de alimentação da região central coincidiu com o ponto crítico alto e houve uma redução das perdas no período diurno. Durante a investigação do ocorrido, mediante modelagem matemática e medições de vazão e pressão em campo, ficou demonstrado que, em um Distrito de Medição e Controle (DMC), quando se tem um único ponto de alimentação e que seja pelo ponto crítico alto, há uma redução das pressões diurnas e, consequentemente, diminuem as taxas de vazamentos / Abstract: The problem of water loss in distribution systems is one of the main challenges faced by the system managers. The purpose of this work is to evaluate a practical case in which the change of the feed point of the network enabled a reduction of water loss due to the reduction of pressures in the studied area. The central region of the city of Cotia, supplied by the Cotia-Jardim Atalaia sector, had the main supply point located far from the critical (high elevation) point. Due to population growth, this tank had its water demand exceeded, and then the need for the reduction of its operating area appeared. To solve the issue, the study area was removed from Cotia-Jardim Atalaia sector and is now supplied by Cotia-Centro sector that accepted the flow increase. With this change, the new feed point of the central region matched the critical high point and there was a reduction in losses during the day. During the investigation of the incident by mathematical modeling and field flow and pressure measurements, it was shown that, in a District Metered Areas (DMA), when you have a single point of supply that matches the critical high point, there is a reduction in daytime pressures and thus a reduction of leakage rates / Mestrado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/257967
Date26 August 2018
CreatorsCosta, Edson Sene da, 1969-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Vatavuk, Paulo, 1960-, Junior, Edevar Luvizotto, Andrade, Jose Geraldo Pena de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format109 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds