Melhoramento de um sistema de absorção por absorção agua-amonia para a fabricação de gelo

Orientador: Jose Tomaz Vieira Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T07:55:24Z (GMT). No. of bitstreams: 1
PrattsMilanes_RafaelLincoln_M.pdf: 7529457 bytes, checksum: a46683408a5f159faa50eae4fff6c712 (MD5)
Previous issue date: 1997 / Resumo: Neste trabalho tenta-se determinar as melhorias tecnológicas que devem ser feitas em um sistema de refrigeração por absorção que usa o par água-amônia como refrigerante para a fabricação de gelo. O estudo é feito sobre uma planta desse tipo que se encontra atualmente na área de serviços do Hospital das Clínicas da UNICAMP e que foi doada a esta Universidade pela empresa MADEF S.A., produtora deste tipo de fábrica no país. Foram usadas as avaliações energéticas e exergéticas, conjuntamente com o cálculo verificativo de trocadores de calor. Para conseguir isso instalou-se um sistema de aquisição de dados via computador, através do qual obtivemos os valores de pressão e temperatura da solução em diversos pontos, definidos geralmente pela entrada e saída de cada equipamento. Com estes dados determinou-se as propriedades termodinâmicas em cada ponto, com ajuda do software AQUAM, e do diagrama entalpia vs. exergia de Merkel-Bonsjakovich. A partir das avaliações energéticas e exergéticas, conseguiu-se determinar os pontos fracos do sistema, verificando os valores das irreversibilidades de cada equipamento pela aplicação do conceito de geração de entropia (Teorema de Gouy-stodola), metodologia válida para a análise de qualquer tipo de sistema. O sistema avaliado apresentou um coeficiente de operação de 0.42; as maiores irreversibilidades, 32 %, no conjunto gerador coluna de retificação; a maior eficiência exergética, 81 %, no pré-aquecedor de solução rica; e a menor, 14,29 %, no sub-resfriador de líquido. Os cálculos realizados indicam o subdimensionamento do absorvedor, do pré-resfriador de solução pobre, e do condensador evaporativo, pouco tempo de congelamento, baixa concentração de amônia no evaporador, dimensões excessivas da válvula de pressão constante e grandes perdas de calor / Abstract: It is focused the technological developments that must be done on absortion freezing systems using the couple water-ammonia as absorber refrigerant for ice inclustries. This study was made over this kind of plant which actually is found in the service area of Hospital das ClinicaslHC in UNICAMP. That plant was freely given to this University by MADEF S.A., producer of this kind of industry in Brazil. Energetic and exergetic evaluations were used jointly to verificative account of heat exchangers. To achieve this goal it was installed a data adquisition system by means of computer through which we got the pressure and temperature values of the solution in different points, genera1ly defined by input and output of each equipment. Using this data, it was determined the thermod:ynamics properties in each point, with AQUAM software help as well as enthalpy exergy diagram ofMerkel and Bonsjakovic. Since the exergetic and energetic evaluations, it was found the weak points of the system verifying irreversibility values of each equipment by applying the entropy theory concept (Gouy-Stodola's Theorem), which is considered an appropriate methodology to analyze any kind of system. The evaluated system presented a coefficient of performance, COP of 0,42, major irreversibilities representing 32% on the generator complex rectifYing column, a major exergetic efficiency, 81%, in rich solution pre-heating and the minor, 14,29%, in the liquid sub-cooling. The calcu1atedvalues indicate the absorber subdimension of the weak solution pre-cooling and of the evaporative condensation, little time of cooling, low ammonia concentration in the evaporator, excessive size of the constant pressure valve and great heat losses / Mestrado / Mestre em Planejamento de Sistemas Energéticos

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265428
Date27 August 1997
CreatorsPratts Milanes, Rafael Lincoln
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Pereira, José Tomaz Vieira, 1944-, Figueiredo, José Ricardo, Martins, Gilberto
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Planejamento de Sistemas Energéticos
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format90f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds