The thesis is engaged in complete reconstruction of a heat system of a family house with higher heat loss, i.e. heat source, piping and radiators. As a heat source is chosen air-water heat pump. Heat system is designed with panel radiators with regard to minimum building interventions. A required power for hot water heating is calculated and selected a heat pump from suitable power range in combination with storage tank with hot water tank. The bivalent point is determined, as backup source are heating elements installed in storage tank. Drawings and circuit diagrams with safety elements are attached. In the end is calculation of estimated return.