Acurácia da imagem de diferentes tomográfos de feixe cônico na avaliação da cobertura óssea em dentes anteriores

Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-03-13T13:00:53Z
No. of bitstreams: 1
Dissertação_Final.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-03-23T13:22:47Z (GMT) No. of bitstreams: 1
Dissertação_Final.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / Made available in DSpace on 2017-03-23T13:22:47Z (GMT). No. of bitstreams: 1
Dissertação_Final.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / CNPQ / O presente estudo teve como objetivo determinar a acurácia diagnóstica da imagem
obtida a partir de diferentes tomógrafos de feixe cônico na avaliação da presença ou
ausência de cobertura óssea em dentes anteriores. Foram adquiridas imagens de
TCFC da região de maxila e mandíbula de um crânio seco em seis diferentes
tomógrafos: Accuitomo (J. Morita, Kyoto, Japão); CS 9000 3D (Carestream Dental,
Trophy, Marne La Vallée, França); CS 9300 (Carestream Dental, Trophy, Marne La
Vallée, França); Eagle 3D (Dabi Atlante, Oklahoma, EUA); i-CAT Classic (Imaging
Sciences International, Hatfield, Pensilvânia, EUA) e Orthophos XG 3D (Sirona
Dental System, Charlote, EUA). Dois radiologistas avaliaram as imagens e um
ortodontista avaliou o crânio seco. Os resultados demonstraram alta acurácia
diagnóstica na avaliação da cobertura óssea nos tomógrafos estudados, com uma
superioridade do CS 9300, que além de alta acurácia, apresentou alta sensibilidade
e especificidade com um menor tempo de escaneamento e menor exposição do
paciente à radiação ionizante. / This study was carried out to determine the diagnostic accuracy of image obtained
from different cone beam tomography in the evaluation of the presence or absence of
bone coverage in anterior teeth. CBCT images were acquired from the maxillary and
jaw region of a dry skull in six different devices - Accuitomo (J. Morita, Kyoto, Japan);
CS 9000 3D (Carestream Dental, Trophy, Marne La Vallee, France); CS 9300
(Carestream Dental, Trophy, Marne La Vallee, France); Eagle 3D (Dabi Atlante,
Oklahoma, USA); i-CAT Classic (Imaging Sciences International, Hatfield,
Pensilvânia, EUA) and Orthophos XG 3D (Sirona Dental System, Charlotte, USA).
Two radiologists evaluated the images and an orthodontist evaluated the dry skull.
The results showed high diagnostic accuracy in the evaluation of bone coverage in
CBCT scanners, with a superiority of the CS 9300, which in addition to high
accuracy, showed high sensitivity and specificity with less time scanning and less
patient exposure to ionizing radiation.

Identiferoai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/21731
Date January 2016
CreatorsDantas, Luciana Loyola
ContributorsRebello, Iêda Margarida Crusoé Rocha, Rebello, Iêda Margarida Crusoé Rocha, Neves, Frederico Sampaio, Oliveira, Luciana
PublisherFaculdade de Odontologia, Programa de Pós-Graduação em Odontologia e Saúde, UFBA, brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds