Front-end para aparelhos auditivos analógicos utilizando Tranformadas Wavelet

Dissertação (mestrado)—Universidade
de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-09-01T13:38:36Z
No. of bitstreams: 1
2014_LucasAraujoPrataChrisostomo.pdf: 3097278 bytes, checksum: d76564773f12558cbcc6da41ab951070 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-09-29T11:49:49Z (GMT) No. of bitstreams: 1
2014_LucasAraujoPrataChrisostomo.pdf: 3097278 bytes, checksum: d76564773f12558cbcc6da41ab951070 (MD5) / Made available in DSpace on 2014-09-29T11:49:49Z (GMT). No. of bitstreams: 1
2014_LucasAraujoPrataChrisostomo.pdf: 3097278 bytes, checksum: d76564773f12558cbcc6da41ab951070 (MD5) / O uso de filtros analógicos em um sistema de áudio em um aparelho auditivo de processamento tem algumas vantagens quando comparado com sistemas digitais, entre
eles, a relação sinal-ruído (SNR) é maior nesse tipo de tratamento e pode até mesmo
melhorar quando a função usada no filtro é o primeiro dos derivativos Gaussian. Além
disso, com um sistema analógico, o consumo de bateria será mais baixo, então não há
nenhuma necessidade de conversores analógico/digital (ADC) e digital/analógico
(DAC). Este trabalho apresenta a concepção de um sistema analógico de baixa potência
para aparelhos auditivos. Para provar a ideia, vários testes foram feitos, primeiro ao nível do sistema usando o programa MATLAB, SIMULINK ferramenta e todos os sinais presentes na ferramenta mencionada e, em seguida, no nível de circuito com a
ferramenta de cadência para provar o real funcionamento do sistema. Com as aproximações numéricas, conseguiu-se uma função no domínio do tempo que representa o tipo de pulso usado. Com esta nova função, uma manipulação em Laplace domínio foi feito e com o método de Padé. Foi usado para obter a função de
transferência. Finalmente, a função de transferência foi representada no espaço de
estado, porque tem baixa sensibilidade para variações nos valores, além de um incrível
dispersão e gama dinâmica. Através de circuitos de translineares, que foi desenvolvido neste trabalho, foi implementado o filtro. Em primeiro lugar era necessário encontrar uma base matemática para a função de filtro que poderia lidar com o sinal sonoro da melhor forma possível, testes foram feitos e após a definição da função, aproximações numéricas foram feitas no domínio do tempo e de Laplace para obter a função de transferência que foi implementada no espaço de estado [1]. Finalmente, esta representação foi aplicada no circuito e sistema de níveis através de um filtro de translineares. Idealmente, você quer obter um sistema analógico que lida com o som de um
ambientes de ruído e amplificação de voz do presente, ser eliminada ou pelo menos
minimizar tanto quanto possível. Como pode ser visto durante o trabalho, a resposta
chegada foi muito perto o desejado-do uso de ferramentas, cuja confiabilidade goza de
grande aceitação entre a comunidade científica, assim, validar a metodologia proposta. ______________________________________________________________________________ ABSTRACT / The use of analog filters in a system for audio processing in a hearing aid has
some advantages when compared with digital systems, among them, the signal-to-noise
ratio (SNR) is greater in this type of treatment and can even improve when the function used in the filter is the first of the Gaussian derivative. In addition, with an analog system, the battery consumption will be lower, so there is no need for analog/digital converters (ADC) and digital/analog (DAC). This work present the design of a low power analog system for hearing aids. To prove the idea, several tests were made, first at system level using the program MATLAB, SIMULINK tool, and all signals present in the mentioned tool, then in the circuit level with the CADENCE tool to prove the real functioning of the system.
With the numerical approximations, a function was achieved in the time domain that represents the type of pulse used. With this new function, a manipulation in the
Laplace domain was made, and with the Padé method. It was used to obtain the transfer
function. At last, the transfer function was represented in state space, because it has low sensitivity to variations in values, in addition to an amazing sparsity and dynamic range. Through translinear circuits, which was developed in this work, the filter was
implemented. First of all it was necessary to find a mathematical basis for the filter function that could handle the audible signal the best way possible, tests were done and after the function definition, numerical approximations were made in the time domain and Laplace transform to obtain the transfer function that was implemented in the State
space [1]. Finally, this representation was applied in circuit and system levels through a translinear filter. Ideally, you want to get an analog system that deals with the sound of a voice amplification and noise environments present, be eliminated or at least minimized as much as possible. As can be seen in the course of the work, the answer reached was very close to the desired-from the use of tools, whose reliability enjoys wide acceptance among the scientific community, thus validating the methodology proposed.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/16332
Date23 May 2014
CreatorsChrisóstomo, Lucas Araújo Prata
ContributorsHaddad, Sandro Augusto Pavlik
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds