Return to search

Técnica de modificação intraoperatória de endoprotese de ePTFE, para tratamento de aneurismas de aorta abdominal sem colo adequado

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências Médicas, Programa de Pós-Graduação em Ciências Médicas, 2014. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2014-11-18T15:18:55Z
No. of bitstreams: 1
2014_GustavoPaludettoOliveira.pdf: 5627138 bytes, checksum: 182a458d77794e8be7775bf64f7b03e5 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-24T15:52:03Z (GMT) No. of bitstreams: 1
2014_GustavoPaludettoOliveira.pdf: 5627138 bytes, checksum: 182a458d77794e8be7775bf64f7b03e5 (MD5) / Made available in DSpace on 2014-11-24T15:52:03Z (GMT). No. of bitstreams: 1
2014_GustavoPaludettoOliveira.pdf: 5627138 bytes, checksum: 182a458d77794e8be7775bf64f7b03e5 (MD5) / INTRODUÇÃO: Resultados em curto prazo demonstram que os aneurismas abdominais sem colo adequado (<15 mm), também podem ser tratados com sucesso utilizando dispositivos configurados para preservação das artérias viscerais através de “scallops”, fenestrações e ramos. Desenvolvemos uma técnica original de fenestração usando a endoprótese Gore Excluder C3® (W.L. Gore & Ass., USA),para o tratamento de aneurismas sem colo proximal adequado usando fenestrações, garantindo uma área de vedação mínima de 15 milímetros e também para a preservação do fluxo nas artérias viscerais. OBJETIVO: O objetivo dessa técnica é de oferecer uma alternativa eficiente, rápida e de fácil execução para o tratamento endovascular de pacientes com aneurismas de aorta abdominal justa e pararrenais ,sem colo adequado para implante de EP convencionais, em casos de emergência médica e/ou impossibilidade de cirurgica aberta, usando uma endoprótese de ePTFE fenestrada. MÉTODO: Um dispositivo de ePTFE reposicionável Gore Excluder C3® (W.L. Gore & Ass., USA) foi manualmente fenestrado usando material cirúrgico tipo "punch de aorta",sendo suturados fios-guia na borda para obter marcadores radiopacos e para reforçar as fenestrações. que foram posteriormente pré-canuladas com fios-guia 0018". O dispositivo foi “reencapado” usando segmento de um introdutor tipo Dry-seal® (W.L. Gore & Ass., USA) . O dispositivo foi introduzido “in vitro” em um modelo de vidro que imita a anatomia de uma aorta com aneurisma. Manobras para abrir, fechar, girar até encontrar a melhor posição para liberação da endoprótese foram feitas. Através das fenestras, stents grafts foram colocados para as artérias viscerais. RESULTADOS: Foi possível modificar o dispositivo reposicionável Gore Excluder C3 ® sem danificar a estrutura metálica e cobertura de ePTFE preservando sua funcionalidade. O tempo de modificação e de “re-encapamento” foi menor do que uma hora. Não houve vazamentos ou lacunas entre as fenestras e o stents grafts. CONCLUSÃO: A técnica proposta foi eficaz , rápida e não complexa para excluir aneurismas de aorta abdominal sem colo adequado podendo ser utilizada como uma alternativa promissora no tratamento destas lesões. __________________________________________________________________________ ABSTRACT / INTRODUCTION: Short-term results demonstrate that abdominal aneurysms without proper neck (<15 mm), can also be successfully treated with devices configured for preservation of visceral arteries through "scallops", fenestrations and branches. We developed an original technique of endoprosthesis fenestration using the Gore Excluder ® C3 (WL Gore & Ass, USA) device, for the treatment of aneurysms without adequate proximal neck using fenestrations ensuring a minimum sealing area of 15 mm and also preserving the flow in the visceral arteries. OBJECTIVE: The objective of this technique is to provide an efficient, rapid and easy endovascular treatment of patients with abdominal aortic aneurysms without proper neck to implant conventional EP, in cases of medical emergency and / or impossibility of open surgery using a fenestrated endoprosthesis of ePTFE. METHOD: A Gore Excluder ® C3 (WL Gore & Ass, USA) ePTFE device was repositioned manually using fenestrated surgical equipment type "punch aorta", being sutured guidewires on the edge for radiopaque markers and strengthen fenestrations, which were afterwards pre-cannulated with guidewires 0018. The device was re-sheathed using a segment of an introducer ® Dry-seal (specify the company.) It was introduced" in vitro "in an artificial model of aorta (specify ). Maneuvers to open, close and rotate until finding the best position for releasing the endoprosthesis were made. Through fenestrae, stent grafts were placed to the visceral arteries.. RESULTS: It was possible to modify the repositionable device Gore Excluder ® C3 without damaging the metal structure and coverage of ePTFE preserving its functionality. The modification time and "resheeting" was less than one hour. There were no leaks or gaps between fenestrae grafts and stents. CONCLUSION: The proposed technique was effective, fast and not complex to exclude abdominal aortic aneurysms without adequate neck and might a promising alternative for treating such lesions.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/17011
Date28 February 2014
CreatorsOliveira, Gustavo Paludetto
ContributorsKessler, Iruena Moraes
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds