Return to search

Simulação por meio do código MCNPX de tomografia gama e validação com dados experimentais

Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2017-06-09T18:11:57Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Dissertação - final.pdf: 1733080 bytes, checksum: f7cb6d19b01ccf4cefdfe6261cb2a5eb (MD5) / Made available in DSpace on 2017-06-09T18:11:57Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Dissertação - final.pdf: 1733080 bytes, checksum: f7cb6d19b01ccf4cefdfe6261cb2a5eb (MD5)
Previous issue date: 2016-01-14 / Capes / Este trabalho apresenta simulações de Monte Carlo com objeto com forma de meia-lua, densidade e material conhecidos. Foi colocado dentro de um tubo de aço como arranjo de teste para simulação pelo código MCNPX, a fim de ser validada pelas medidas em experimentos estáticos de transmissão de raios gama e com comparação com dados teóricos. O MCNPX requer uma geometria definida para cada trajetória de fótons. Isto oferece empecilhos para o uso do código em simulação de tomografia. A solução desse problema foi escrever um programa para criar os arquivos de entrada para cada trajetória. Trabalhando nesta sequência, foi criado um banco de dados para organização da grande quantidade de dados gerados. A instalação experimental utiliza um único par fonte-detector, com fonte radioativa isotópica de Césio-137 e o detector de Nal (Tl) de cintilação acoplado a um analisador de multicanal. A análise de erros foi feita com a métrica do RMSE para avaliação da qualidade das simulações. As simulações foram validadas pelos dados experimentais e também pelos dados analíticos com erros satisfatórios segundo a métrica utilizada. / This work presents Monte Carlo simulations with object shaped like a half moon with density and material knowns. It was placed inside a steel tube as a test arrangement for simulating the MCNPX code, for validation by static experiments measurement of gamma ray transmission and compared with theoretical data. The MCNPX requires a geometry defined for each photon trajectory. This offers trammels to use the code for tomography simulation. The solution of this problem was developing a program to create input files for each trajectory. Working in this sequence, a database was created to organize large amount of data has been generated. The experimental setup uses a single source-detector pair, with a radioactive isotope Cesium source 137 and the detector NaI (Tl) scintillation coupled to a multichannel analyzer. The error analysis was made with the RMSE metric for evaluating the quality of the simulations. The simulations were validated by experimental data and also by comparison with theoretical data with satisfactory errors according to the metric used.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/19073
Date14 January 2016
CreatorsGUEDES, Karlos André Negri
Contributorshttp://lattes.cnpq.br/6187057688601197, DANTAS, Carlos Costa
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Tecnologias Energeticas e Nuclear, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.1601 seconds