The objective of this master thesis was to study the performance of an active triangulation system for 3-D imaging in underwater applications. Structured light from a 20 mW laser and a conventional video camera was used to collect data for generation of 3-D images. Different techniques to locate the laser line and transform it into spatial coordinates were developed and evaluated. A field- and a laboratory trial were performed. From the trials we can conclude that the distance resolution is much higher than the lateral- and longitudinal resolution. The lateral resolution can be improved either by using a high frame rate camera or simply by using a low scanning speed. It is possible to obtain a range resolution of less than a millimeter. The maximum range of vision was 5 meters under water measured on a white target and 3 meters for a black target in clear sea water. These results are however dependent on environmental and system parameters such as laser power, laser beam divergence and water turbidity. A higher laser power would for example increase the maximum range.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:liu-6125 |
Date | January 2006 |
Creators | Norström, Christer |
Publisher | Linköpings universitet, Bildbehandling, Linköpings universitet, Tekniska högskolan, Institutionen för systemteknik |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, info:eu-repo/semantics/bachelorThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds