In hydraulic-mechanically controlled variable displacement pumps, the actual pump controller produces additional power losses. Due to the low damping coefficients of all pump controller’s components, hydraulic-mechanically pressure controlled pumps use to oscillate while adjusting the pressure level in the hydraulic system. In several state-of-the-art variable pump controllers, a damping orifice connects the control actuator’s displacement chamber with the reservoir. This bypass dampens the movement of the control actuator but also leads to bypass losses during steady-state operation of the pump. A new concept for damping via feedback loops avoiding bypass losses is presented in t his paper.
Identifer | oai:union.ndltd.org:DRESDEN/oai:qucosa:de:qucosa:71108 |
Date | 25 June 2020 |
Creators | Schoemacker, Florian, Fischer, Felix, Schmitz, Katharina |
Contributors | Dresdner Verein zur Förderung der Fluidtechnik e. V. Dresden |
Publisher | Technische Universität Dresden |
Source Sets | Hochschulschriftenserver (HSSS) der SLUB Dresden |
Language | English |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, doc-type:conferenceObject, info:eu-repo/semantics/conferenceObject, doc-type:Text |
Rights | info:eu-repo/semantics/openAccess |
Relation | 10.25368/2020.6, urn:nbn:de:bsz:14-qucosa2-709160, qucosa:70916 |
Page generated in 0.002 seconds