Return to search

Proteção diferencial de barramentos baseada na transformada wavelet

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-08-05T12:38:46Z
No. of bitstreams: 1
2016_AlfredoMiguelPianetaEscudero.pdf: 3029900 bytes, checksum: a90bedf1eff29217006b113b0287ba44 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-08-25T21:24:55Z (GMT) No. of bitstreams: 1
2016_AlfredoMiguelPianetaEscudero.pdf: 3029900 bytes, checksum: a90bedf1eff29217006b113b0287ba44 (MD5) / Made available in DSpace on 2016-08-25T21:24:55Z (GMT). No. of bitstreams: 1
2016_AlfredoMiguelPianetaEscudero.pdf: 3029900 bytes, checksum: a90bedf1eff29217006b113b0287ba44 (MD5) / Apresenta-se neste trabalho a implementação e testes de uma nova função de proteção diferencial numérica de baixa impedância para barramentos, na qual os conceitos da proteção diferencial tradicional são mapeados para a teoria da transformada wavelet. Para tanto, energias de operação e restrição são calculadas utilizando os coeficientes wavelet e escala obtidos a partir dos sinais de corrente medidos no sistema monitorado. Tradicionalmente, a operação da proteção de barramentos se baseia nos elementos filtrados, ou seja, nos fasores fundamentais, o que resulta em atrasos adicionais nas atuações da proteção. Neste trabalho, utilizam-se elementos instantâneos para reduzir os tempos de atuação. O critério de operação da proteção se baseia nas lógicas de atuação 1-de-1 e 2-de-2, as quais têm sido amplamente empregadas em relés reais disponíveis no comércio. Para avaliar a função de proteção proposta, diferentes condições de operação de um sistema de barra dupla de 230 kV foram simulados no AlternativeTransientsProgram (ATP). Os resultados obtidos revelam que o esquema de proteção diferencial de barramentos proposto opera de forma seletiva em casos de faltas internas e externas ao barramento, resultando em tempos de atuação menores que 1 milissegundo, mesmo quando aplicado em subestações com configurações complexas e flexíveis. Além o esquema garante a operação estável durante condições de saturação de transformadores de corrente para faltas externas, considerada a situação mais adversa que pode afetar a proteção de barramentos, levando a eventuais operações indevidas da mesma. ________________________________________________________________________________________________ ABSTRACT / This work presents the implementation and test of a new numerical lowimpedance busbar differential protection function, in which the fundamentals of traditional differential protection are adapted to the wavelet transform domain. In order to do so, operating and restraint energies are computed using the wavelet and scaling coefficients obtained from the current signals measured in the monitored system. Traditionally, the differential protection is based on filtered elements, i.e., in fundamental phasors, what results in additional operation delays. In this work, instantaneous elements are used in order to reduce the protection operation time. The 1-out-of-1 and 2-out-of-2 operating tripping logics are used, which have been widely applied in actual numerical relays commercially available. To evaluate the proposed protection function, different operating conditions of a 230 kV double busbar arrangement were simulated in the Alternative Transients Program (ATP). The obtained results reveal that the proposed busbar protection scheme is selective in cases of faults internal and external to the monitored busbar, resulting in protection operation times less than 1millisecond, even when it is applied in substations with complex and flexible topologies.Also the protection scheme remains stable operations during external faults with external fault saturation.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/21339
Date20 June 2016
CreatorsEscudero, Alfredo Miguel Pianeta
ContributorsSilva, Kleber Melo e
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0153 seconds