Orientador: Ronilson Agnaldo Moreno / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T23:39:10Z (GMT). No. of bitstreams: 1
Rigato_HamiltonModesto_M.pdf: 3336408 bytes, checksum: 6361b337850dbff27073d971e3c03509 (MD5)
Previous issue date: 2005 / Resumo: Objetivo: Neste estudo a biodisponibilidade de duas formulações de meloxicam (comprimidos de 15mg) foram comparadas. Uma dose de cada formulação foi administrada em 24 voluntários sadios de ambos os sexos. Materiais e métodos: O estudo foi do tipo aberto, aleatório, cruzado, em dois períodos. As amostras de sangue foram colhidas em intervalos de até 96 horas e as concentrações de meloxicam foram analisadas em cromatografia líquida de alta performance (Agilent), acoplada ao espectrômetro de massa (API 2000) equipadas com fonte de ionização do tipo electrospray operando no modo positivo (ES+) com monitorização de reações múltiplas (MRM). O precipitado plasmático protéico foi reconstituído com uma solução de acetonitrila/água + ácido acético 10mM (20/80; vv) e injetados na coluna analítica {(prevail Cs 5µm (150mm x 4.6 mm i.d.)} do cromatógrafo de fase líquida. O tempo de retenção observado para o meloxicam e tenoxicam (padrão interno) foi de 1.8 e 1.4 min respectivamente. A média de recuperação do meloxicam foi 95.9% e o limite de quantificação foi de 0.02lµg/mL. Resultados: As razões geométricas para o Meloxicam/Movatec@ 15 mg foram 101.3% para a ASCúltimo;9.9% para a ASCinfe 107.7% para a Cmax. Os intervalos de confiança de 90% foram 97.3-105.4%; 96.0 - 104.0% e 98.8 - 117.4% respectivamente. Conclusão: Considerando que 90% dos intervalos de confiança das razões de ASC último, ASCinf e Cmax se encontram dentro de 80-125% do intervalo proposto pela Agência Americana de Alimentos e Medicamentos (US FDA) e aceita pela ANVISA (Agência Nacional de Vigilância Sanitária), concluiu-se que a formulação de meloxicam elaborado pela Merk S.A. Indústrias Químicas é bioequivalente a formulação do Movatec@ em relação à taxa e extensão de absorção. Esse método de ensaio é o mais rápido, simples, específico, preciso e com acurácia, para os estudos de bioequivalência, que os previamente descritos / Abstract: Objective: In this study, the bioavailability of 2 meloxicam 15 mg tablet formulations was compared. A single dose of each formulation was administered to 24 healthy volunteers (12 males and 12 femates). Material and Methods: The study was conducted using an opeo, randomized and crossover design with a 2-week washout interval. The Plasma samples were obtained over 96-hour interval and meloxicam concentrations were analyzed by high performance liquid chromatography (an Agilent) coupled to a API 2000 turboionspray tandem mass spectrometry (LC-MS-MS) equipped with an electrospray ionization (ESI) source operating in the positive ion mode using a cross flow counter electrode and set for the multiple reaction monitoring (MRM). The plasma protein precipitated was reconstituted with acetonitrile/water + 10mM acetic acid (20/80; v/v), and inject in a Prevail Cs 5J/m (150mm x 4.6 mm i.d.) analytical column reverse phase liquid chromatography. The retention time observed for meloxicam and tenoxicam (Internal Standard) was 1.8 and 1.4 mio, respectively. The mean recovery of meloxicam was 95.9% and the Limit of Quantification was 0.02 J-lg/mL. Results: Geometric mean of MeloxicamlMovatec@ 15 mg individual percent ratio was 101.3% for AVCIast,99.9% for AVCo-ooand 107.7% for Crnax.The 90% confidence interval was 97.3-105.4%; 96.0 - 1O4.00/Óand 98.8 - 117.4%, respectively. Conclusion: Since the 90% CI for both AVCIast,AVCo-ooand Cmax,ratios were all inside the 80-125% interval proposed by the VS Food and Drug Administration Agency and accept by Brazilian ANVISA (Sanitary Surveillance Agency), it was concluded that meloxicam formulation elaborated by Merck S.A. Indústrias Químicas is bioequivalent to Movateca formulation for both the rate and the extent of absorption. This assay method was a fast, simple, specific, precise and accurate for the bioequivalence study of meloxicam than has previously been described. / Mestrado / Mestre em Farmacologia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311847 |
Date | 31 August 2005 |
Creators | Rigato, Hamilton Modesto, 1977- |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Moreno, Ronilson Agnaldo, Pereira, Alberto dos Santos, Mendes, Gun Birgitta Bergsten |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Farmacologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 67f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0027 seconds