The objective of the present work is the study of the electrochemical behaviour of two diagnostic tumor markers of great importance, vanillylmandelic acid (VMA) and homovanillic acid (HVA), on carbon-based electrodes by using cyclic and differential pulse voltammetry. A comparison was made among non-modified glassy carbon electrode (GCE) and GCE modified by multi-walled carbon nanotubes, Nafion (Nafion/GCE) and poly(neutral red) (PNR/GCE), and further boron doped diamond (BDD) electrode which was activated by anodic polarization (Eakt = +2,4 V, t = 30 s) or by polishing on alumina slurry. Significant differences in the voltammetric responses of VMA and HVA were found, not only among utilized electrode materials which also influenced the way of controlling the oxidation process, but also they depend on the pH value of aqueous media in which these acids occurred. An acidic environment is the most suitable for their determination. Calibration dependences were measured in 0.1 mol∙l−1 phosphate buffer pH 3.0 which was chosen as an optimal supporting electrolyte for differential pulse voltammetric determination. Achieved detection limits were 0.6, 0.9, 0.8 and 1.2 μmol∙l−1 for HVA and 0.4, 1.5, 2.4 and 1.1 μmol∙l−1 for VMA at BDD electrode, non-modified GCE, Nafion/GCE and PNR/GCE, respectively. Limits...
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:356341 |
Date | January 2017 |
Creators | Baluchová, Simona |
Contributors | Schwarzová, Karolina, Dejmková, Hana |
Source Sets | Czech ETDs |
Language | Slovak |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.002 seconds